062 Three consecutive startup failures Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), select Load Default Settings , make sure that the date and time are correct, and save the settings. Reseat the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 101 Timer tick interrupt failure (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 102 Timer 2 test failure (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 106 Diskette controller failure 151 Real time clock failure Reseat the battery - See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting ( and Turning on the blade server ) the blade server each time:Battery - See Removing the battery , and Installing the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 161 Real-time clock battery failure Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), select Load Default Settings and save the settings. Reseat the battery - See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 162 Invalid configuration information or CMOS RAM checksum failure. Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), select Load Default Settings and save the settings. Reseat the battery - See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 163 Time of day not set. Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), select Load Default Settings , and make sure that the date and time are correct, and save the settings. Reseat the battery - See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 184 Bad power-on password. Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), select Load Default Settings and save the settings. Reseat the battery - See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 188 Bad EEPROM CRC #2 (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 189 Three attempts to enter the incorrect password. Restart the blade server, run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), and change the power-on password (Using passwords ). 289 Memory error Run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), disable the problem DIMMs under select Advanced Setup → Memory Settings , and save the settings. If an expansion unit is installed, reseat it. See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time.DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . 301 Keyboard failure. If you have installed a USB keyboard, run the Configuration/Setup Utility program (Using the Configuration/Setup Utility program ), and enable the keyboardless operation to prevent the POST error message 301 from being displayed during startup. Check the function of the shared BladeCenter® unit resources. See Solving shared BladeCenter resource problems . (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 602 Invalid diskette boot record. Check the function of the shared BladeCenter unit resources. See Solving shared BladeCenter resource problems . (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 604 Diskette drive failure. Check the function of the shared BladeCenter unit resources. See Solving shared BladeCenter resource problems . (Trained service technician only) Replace the system-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1200 Processor machine check. (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor. - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1762 Hard disk drive configuration has changed. Run the Configuration/Setup Utility program, make sure that the hard disk drive configuration is correct, and save the settings. See Using the Configuration/Setup Utility program . Reseat the storage drives. Depending on your storage drive configuration, use the following information to reseat your storage drives: If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Storage drives: Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1800 No more IRQs available. Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated - See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card and Installing an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1801 No more room for option ROM. Run the Configuration/Setup Utility program and make sure that the PXE settings are correct. Disabling PXE can allow more optional devices to be managed. See Using the Configuration/Setup Utility program . Use the Configuration/Setup Utility program (Advanced Setup → PCI Bus Control → PCI ROM Control ) to disable each optional device one at a time, restarting the blade server each time, until the 1801 error code is cleared. Optional devices that cause the 1801 error code are the I/O expansion cards and expansion units. Disable these optional devices in the order of least-to-most important. Remove each optional device one at a time, restarting the blade server each time, until the 1801 error code is cleared. Optional devices that cause the 1801 error code are the I/O expansion cards and optional expansion unit. Remove these optional devices in the order of least-to-most important. See the following optional device procedures: (Trained service technician only) If the problem remains after all optional devices have been removed, replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 1802 No more I/O space available. Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See the following optional device procedures: If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1803 No more memory (above 1 MB) available. Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated - See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1804 No more memory (below 1 MB) available. Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1805 Checksum error or 0 size option ROM. Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1806 PCI device failed BIST. Run the Configuration/Setup Utility program) and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1807 System board device did not respond or was disabled by the user. Run the Configuration/Setup Utility program and make sure that interrupt resource settings are correct. See Using the Configuration/Setup Utility program . Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card and Installing an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1808 Invalid header. Run the Configuration/Setup Utility program (Setup and configuration overview ) and make sure that interrupt resource settings are correct. Remove each I/O expansion card one at a time, restarting the blade server each time, until the problem is isolated. See Turning off the blade server Removing an I/O expansion card and Turning on the blade server . If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components one at a time, in the order shown, restarting the blade server each time:Failed I/O expansion card - See Removing an I/O expansion card andInstalling an I/O expansion card . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1962 Boot sector error, no operating system installed. Make sure that a bootable operating system is installed. Installing the operating system . Run the SAS Attached Disk diagnostic test - See Dynamic system analysis diagnostic programs and messages . Reseat the storage drive. Depending on your storage drive configuration, use the following information to reseat your storage drives: Replace the following components one at a time, in the order shown, restarting the blade server each time:Storage drive - Depending on your storage-drive configuration, replace one of the following: (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00012000 Processor machine check (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 000197 Processor P failed BIST (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components, one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150100 Multi-bit error occurred: forcing NMI DIMM=xx DIMM=yy (could not isolate) Reseat following components one at a time, in the order shown, restarting the blade server each time:DIMMs xx and yy - . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . Replace the following components, one at a time, in the order shown, restarting the blade server each time:DIMMs xx and yy - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150200 SERR: Addr or Spec. Cyc. DPE Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150300 SERR: Received Target Abort Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150400 SERR: Device Signaled SERR Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150500 PERR: Master Read parity error Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150600 PERR: Primary Write parity error Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150700 PERR: Secondary signaled parity error Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00150900 SERR/PERR Detected on PCI bus (no source found) If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat each I/O expansion card, restarting the blade server each time. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151000 SERR: Signaled Target Abort Slot=xx Vendor ID=xxxx Device ID=xxxx Status=xxxx If an optional expansion unit is installed, reseat it - See Removing an optional expansion unit and Installing an optional expansion unit . Reseat the I/O expansion card in slot xx ; then, restart the blade server. Replace the following components, one at a time, in the order shown, restarting the blade server each time:I/O expansion card in slot xx - Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151100 MCA: Recoverable Error Detected Proc Reseat the microprocessor. Replace the following components, one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151200 MCA: Unrecoverable Error Detected Proc (Trained service technician only) Reseat the microprocessor. Replace the following components, one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151300 MCA: Excessive Recoverable Error Detected Proc (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151350 Processor Machine Check Data a Bank= xx APIC ID=xx CR4=xxxx xxxx Additional data for debugging. See error codes 00151100, 00151200, and 00151300 for action. 00151351 Processor Machine Check Data b Address= xxxx xxxx xxxx xxxx Time stamp=xxxx xxxx xxxx xxxx Additional data for debugging. See error codes 00151100, 00151200, and 00151300 for action. 00151352 Processor Machine Check Data b Status= xxxx xxxx xxxx xxxx Additional data for debugging. See error codes 00151100, 00151200, and 00151300 for action. If bit 10 of Data b status is set, do not replace the microprocessor. 00151500 Excessive Single Bit Errors Detected DIMM=xx Reseat DIMM xx and the expansion unit if one is installed. Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMM xx - See Removing a memory module and Installing a memory module . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151700 Started Hot Spare memory Copy. Failed row/rows=xx and yy copied to spare row/rows=aa and bb Reseat a DIMM - See Removing a memory module and Installing a memory module . See error code 00151500 to determine which DIMM to reseat. Replace a DIMM - See Removing a memory module and Installing a memory module . See error code 00151500 to determine which DIMM to replace. 00151710 Completed Hot Spare memory Copy. Failed row/rows=xx and yy copied to spare row/rows=aa and bb Reseat a DIMM - See Removing a memory module and Installing a memory module . See error code 00151500 to determine which DIMM to reseat. Replace a DIMM - See Removing a memory module and Installing a memory module . See error code 00151500 to determine which DIMM to replace. 00151720 Parity Error Reseat the microprocessor. Detected on Processor bus. (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 00151730 CRC Error Reseat all DIMMs - See Removing a memory module and Installing a memory module .
01295085 ECC checking hardware test failed (Trained service technician only) Reseat the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components, one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 012980xx The BIOS does not support the Processor Pxx Make sure that the microprocessor is supported. Update the blade server firmware. Go to http://www.ibm.com/systems/support/ . 012981xx Unable to apply the Microcode Update for Processor xx Make sure that the microprocessor is supported. Replace the microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . I9990303 No Boot devices found Install the operating system on the storage drive - See Installing the operating system .
I999301 Fixed disk boot sector error. Reseat the storage drive. Depending on your storage drive configuration, use the following information to reseat your storage drives: Replace the following components one at a time, in the order shown, restarting the blade server each time:Storage drive - Depending on your storage-drive configuration, replace one of the following: (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly .