Skip to main content

Port assignments for FC switches when using ONTAP 9.4 and later

You need to verify that you are using the specified port assignments when you cable the FC switches when using ONTAP 9.4 and later.

Ports that are not used for attaching initiator ports, FC-VI ports, or ISLs can be reconfigured to act as storage ports. However, if the supported RCFs are being used, the zoning must be changed accordingly.

If the supported RCFs are used, ISL ports might not connect to the same ports shown here and might need to be reconfigured manually.

If you configured your switches using the port assignments for ONTAP 9, you can continue to use the older assignments. However, new configurations running ONTAP 9.4 or later releases should use the port assignments shown here.

Overall cabling guidelines

You should be aware of the following guidelines when using the cabling tables:
  • The Brocade and Cisco switches use different port numbering:

    • On Brocade switches, the first port is numbered 0.

    • On Cisco switches, the first port is numbered 1.

  • The cabling is the same for each FC switch in the switch fabric.

  • AFA DM7000F and DM7000H storage systems can be ordered with one of two options for FC-VI connectivity:
    • Onboard ports 0e and 0f configured in FC-VI mode.

    • Ports 1a and 1b on an FC-VI card in slot 1.

  • DM7100F and DM7100H storage systems use ports 2a and 2b for FC-VI connectivity.
  • If you have two MetroCluster configurations sharing ISLs, use the same port assignments as that for an eight-node MetroCluster cabling.

    The number of ISLs you cable may vary depending on your site's requirements.

Brocade port usage for controllers in a MetroCluster configuration running ONTAP 9.4 or later

The following tables show port usage on Brocade switches. The tables show the maximum supported configuration, with eight controller modules in two DR groups. For smaller configurations, ignore the rows for the additional controller modules. Note that eight ISLs are supported only on the Lenovo B6510, DB620S, and DB630S switches.

Note
Port usage for the Lenovo B6505 FC SAN switch and Lenovo ThinkSystem DB610S 32G FC SAN switch switches in an eight-node MetroCluster configuration is not shown. Due to the limited number of ports, port assignments must be made on a site-by-site basis depending on the controller module model and the number of ISLs and bridge pairs in use.
Configurations using FibreBridge 7600N using one FC port (FC1 or FC2) only
MetroCluster 1 or DR Group 1
ComponentPortLenovo switch models B6505, B6510, DB610S, DB620S, DB630S
Connects to FC switch...Connects to switch port...
controller_x_1FC-VI port a10
FC-VI port b20
FC-VI port c11
FC-VI port d21
HBA port a12
HBA port b22
HBA port c13
HBA port d23
controller_x_2FC-VI port a14
FC-VI port b24
FC-VI port c15
FC-VI port d25
HBA port a16
HBA port b26
HBA port c17
HBA port d27
Stack 1bridge_x_1a18
bridge_x_1b28
Stack 2bridge_x_2a19
bridge_x_2b29
Stack 3bridge_x_3a110
bridge_x_4b210
Stack ybridge_x_ya111
bridge_x_yb211
Note
  • On DB620S and DB630S switches, additional bridges can be cabled to ports 12 - 17, 20 and 21.

  • On DB610S switches, additional bridges can be cabled to ports 12 - 19.

Configurations using FibreBridge 7600N using one FC port (FC1 or FC2) only
MetroCluster 2 or DR Group 2
   Brocade switch model
ComponentPortConnects to FC_switch...B6510DB620S, DB630S
controller_x_3FC-VI port a12418
FC-VI port b22418
FC-VI port c12519
FC-VI port d22519
HBA port a12624
HBA port b22624
HBA port c12725
HBA port d22725
controller_x_4FC-VI port a12822
FC-VI port b22822
FC-VI port c12923
FC-VI port d22923
HBA port a13028
HBA port b23028
HBA port c13129
HBA port d23229
Stack 1bridge_x_51a13226
bridge_x_51b23226
Stack 2bridge_x_52a13327
bridge_x_52b23327
Stack 3bridge_x_53a13430
bridge_x_54b23430
Stack ybridge_x_ya13531
bridge_x_yb23531
Configurations using 7600N using both FC ports (FC1 and FC2)
MetroCluster 1 or DR Group 1
ComponentPortBrocade switch models B6505, B6510, DB610S, DB620S, DB630S
Connects to FC_switch...Connects to switch port...
controller_x_1FC-VI port a10
FC-VI port b20
FC-VI port c11
FC-VI port d21
HBA port a12
HBA port b22
HBA port c13
HBA port d23
controller_x_2FC-VI port a14
FC-VI port b24
FC-VI port c15
FC-VI port d25
HBA port a16
HBA port b26
HBA port c17
HBA port d27
Stack 1bridge_x_1aFC118
FC228
bridge_x_1BFC119
FC229
Stack 2bridge_x_2aFC1110
FC2210
bridge_x_2BFC1111
FC2211
Stack 3bridge_x_3aFC1112*
FC2212*
bridge_x_3BFC1113*
FC2213*
Stack ybridge_x_yaFC1114*
FC2214*
bridge_x_ybFC1115*
FC2215*
Note
Additional bridges can be cabled to ports 16, 17, 20 and 21 in DB620S and DB630S switches.
Configurations using FibreBridge 7600N using both FC ports (FC1 and FC2)
MetroCluster 2 or DR Group 2
ComponentPortBrocade switch model
Connects to FC_switch...B6510DB620S, DB630S
controller_x_3FC-VI port a12418
FC-VI port b22418
FC-VI port c12519
FC-VI port d22519
HBA port a12624
HBA port b22624
HBA port c12725
HBA port d22725
controller_x_4FC-VI port a12822
FC-VI port b22822
FC-VI port c12923
FC-VI port d22923
HBA port a13028
HBA port b23028
HBA port c13129
HBA port d23129
Stack 1bridge_x_51aFC113226
FC223226
bridge_x_51bFC113327
FC223327
Stack 2bridge_x_52aFC113430
FC223430
bridge_x_52bFC113531
FC223531
Stack 3bridge_x_53aFC113632
FC223632
bridge_x_53bFC113733
FC223733
Stack ybridge_x_5yaFC113834
FC223834
bridge_x_5ybFC113935
FC223935
Note
Additional bridges can be cabled to ports 36 to 39 in DB620S and DB630S switches.

Brocade port usage for ISLs in a MetroCluster configuration running ONTAP 9.4 or later

The following table shows ISL port usage for the Brocade switches.

Switch modelISL portSwitch port
Lenovo B6505 FC SAN switchISL port 120
ISL port 221
ISL port 322
ISL port 423
Lenovo B6510ISL port 140
ISL port 241
ISL port 342
ISL port 443
ISL port 544
ISL port 645
ISL port 746
ISL port 847
Brocade G610ISL port 120
ISL port 221
ISL port 322
ISL port 423
Lenovo ThinkSystem DB620S 32G FC SAN switch and Lenovo ThinkSystem DB630S 32G FC SAN switchISL port 140
ISL port 241
ISL port 342
ISL port 443
ISL port 544
ISL port 645
ISL port 746
ISL port 847