Port assignments for FC switches when using ONTAP 9.4 and later
You need to verify that you are using the specified port assignments when you cable the FC switches when using ONTAP 9.4 and later.
Ports that are not used for attaching initiator ports, FC-VI ports, or ISLs can be reconfigured to act as storage ports. However, if the supported RCFs are being used, the zoning must be changed accordingly.
If the supported RCFs are used, ISL ports might not connect to the same ports shown here and might need to be reconfigured manually.
If you configured your switches using the port assignments for ONTAP 9, you can continue to use the older assignments. However, new configurations running ONTAP 9.4 or later releases should use the port assignments shown here.
Overall cabling guidelines
The Brocade and Cisco switches use different port numbering:
On Brocade switches, the first port is numbered 0.
On Cisco switches, the first port is numbered 1.
The cabling is the same for each FC switch in the switch fabric.
- AFA DM7000F and DM7000H storage systems can be ordered with one of two options for FC-VI connectivity:
Onboard ports 0e and 0f configured in FC-VI mode.
Ports 1a and 1b on an FC-VI card in slot 1.
- DM7100F and DM7100H storage systems use ports 2a and 2b for FC-VI connectivity.
If you have two MetroCluster configurations sharing ISLs, use the same port assignments as that for an eight-node MetroCluster cabling.
The number of ISLs you cable may vary depending on your site's requirements.
Brocade port usage for controllers in a MetroCluster configuration running ONTAP 9.4 or later
The following tables show port usage on Brocade switches. The tables show the maximum supported configuration, with eight controller modules in two DR groups. For smaller configurations, ignore the rows for the additional controller modules. Note that eight ISLs are supported only on the Lenovo B6510, DB620S, and DB630S switches.
Configurations using FibreBridge 7600N using one FC port (FC1 or FC2) only | |||
---|---|---|---|
MetroCluster 1 or DR Group 1 | |||
Component | Port | Lenovo switch models B6505, B6510, DB610S, DB620S, DB630S | |
Connects to FC switch... | Connects to switch port... | ||
controller_x_1 | FC-VI port a | 1 | 0 |
FC-VI port b | 2 | 0 | |
FC-VI port c | 1 | 1 | |
FC-VI port d | 2 | 1 | |
HBA port a | 1 | 2 | |
HBA port b | 2 | 2 | |
HBA port c | 1 | 3 | |
HBA port d | 2 | 3 | |
controller_x_2 | FC-VI port a | 1 | 4 |
FC-VI port b | 2 | 4 | |
FC-VI port c | 1 | 5 | |
FC-VI port d | 2 | 5 | |
HBA port a | 1 | 6 | |
HBA port b | 2 | 6 | |
HBA port c | 1 | 7 | |
HBA port d | 2 | 7 | |
Stack 1 | bridge_x_1a | 1 | 8 |
bridge_x_1b | 2 | 8 | |
Stack 2 | bridge_x_2a | 1 | 9 |
bridge_x_2b | 2 | 9 | |
Stack 3 | bridge_x_3a | 1 | 10 |
bridge_x_4b | 2 | 10 | |
Stack y | bridge_x_ya | 1 | 11 |
bridge_x_yb | 2 | 11 | |
Note
|
Configurations using FibreBridge 7600N using one FC port (FC1 or FC2) only | ||||
---|---|---|---|---|
MetroCluster 2 or DR Group 2 | ||||
Brocade switch model | ||||
Component | Port | Connects to FC_switch... | B6510 | DB620S, DB630S |
controller_x_3 | FC-VI port a | 1 | 24 | 18 |
FC-VI port b | 2 | 24 | 18 | |
FC-VI port c | 1 | 25 | 19 | |
FC-VI port d | 2 | 25 | 19 | |
HBA port a | 1 | 26 | 24 | |
HBA port b | 2 | 26 | 24 | |
HBA port c | 1 | 27 | 25 | |
HBA port d | 2 | 27 | 25 | |
controller_x_4 | FC-VI port a | 1 | 28 | 22 |
FC-VI port b | 2 | 28 | 22 | |
FC-VI port c | 1 | 29 | 23 | |
FC-VI port d | 2 | 29 | 23 | |
HBA port a | 1 | 30 | 28 | |
HBA port b | 2 | 30 | 28 | |
HBA port c | 1 | 31 | 29 | |
HBA port d | 2 | 32 | 29 | |
Stack 1 | bridge_x_51a | 1 | 32 | 26 |
bridge_x_51b | 2 | 32 | 26 | |
Stack 2 | bridge_x_52a | 1 | 33 | 27 |
bridge_x_52b | 2 | 33 | 27 | |
Stack 3 | bridge_x_53a | 1 | 34 | 30 |
bridge_x_54b | 2 | 34 | 30 | |
Stack y | bridge_x_ya | 1 | 35 | 31 |
bridge_x_yb | 2 | 35 | 31 |
Configurations using 7600N using both FC ports (FC1 and FC2) | ||||
---|---|---|---|---|
MetroCluster 1 or DR Group 1 | ||||
Component | Port | Brocade switch models B6505, B6510, DB610S, DB620S, DB630S | ||
Connects to FC_switch... | Connects to switch port... | |||
controller_x_1 | FC-VI port a | 1 | 0 | |
FC-VI port b | 2 | 0 | ||
FC-VI port c | 1 | 1 | ||
FC-VI port d | 2 | 1 | ||
HBA port a | 1 | 2 | ||
HBA port b | 2 | 2 | ||
HBA port c | 1 | 3 | ||
HBA port d | 2 | 3 | ||
controller_x_2 | FC-VI port a | 1 | 4 | |
FC-VI port b | 2 | 4 | ||
FC-VI port c | 1 | 5 | ||
FC-VI port d | 2 | 5 | ||
HBA port a | 1 | 6 | ||
HBA port b | 2 | 6 | ||
HBA port c | 1 | 7 | ||
HBA port d | 2 | 7 | ||
Stack 1 | bridge_x_1a | FC1 | 1 | 8 |
FC2 | 2 | 8 | ||
bridge_x_1B | FC1 | 1 | 9 | |
FC2 | 2 | 9 | ||
Stack 2 | bridge_x_2a | FC1 | 1 | 10 |
FC2 | 2 | 10 | ||
bridge_x_2B | FC1 | 1 | 11 | |
FC2 | 2 | 11 | ||
Stack 3 | bridge_x_3a | FC1 | 1 | 12* |
FC2 | 2 | 12* | ||
bridge_x_3B | FC1 | 1 | 13* | |
FC2 | 2 | 13* | ||
Stack y | bridge_x_ya | FC1 | 1 | 14* |
FC2 | 2 | 14* | ||
bridge_x_yb | FC1 | 1 | 15* | |
FC2 | 2 | 15* | ||
Note Additional bridges can be cabled to ports 16, 17, 20 and 21 in DB620S and DB630S switches. |
Configurations using FibreBridge 7600N using both FC ports (FC1 and FC2) | ||||||
---|---|---|---|---|---|---|
MetroCluster 2 or DR Group 2 | ||||||
Component | Port | Brocade switch model | ||||
Connects to FC_switch... | B6510 | DB620S, DB630S | ||||
controller_x_3 | FC-VI port a | 1 | 24 | 18 | ||
FC-VI port b | 2 | 24 | 18 | |||
FC-VI port c | 1 | 25 | 19 | |||
FC-VI port d | 2 | 25 | 19 | |||
HBA port a | 1 | 26 | 24 | |||
HBA port b | 2 | 26 | 24 | |||
HBA port c | 1 | 27 | 25 | |||
HBA port d | 2 | 27 | 25 | |||
controller_x_4 | FC-VI port a | 1 | 28 | 22 | ||
FC-VI port b | 2 | 28 | 22 | |||
FC-VI port c | 1 | 29 | 23 | |||
FC-VI port d | 2 | 29 | 23 | |||
HBA port a | 1 | 30 | 28 | |||
HBA port b | 2 | 30 | 28 | |||
HBA port c | 1 | 31 | 29 | |||
HBA port d | 2 | 31 | 29 | |||
Stack 1 | bridge_x_51a | FC1 | 1 | 32 | 26 | |
FC2 | 2 | 32 | 26 | |||
bridge_x_51b | FC1 | 1 | 33 | 27 | ||
FC2 | 2 | 33 | 27 | |||
Stack 2 | bridge_x_52a | FC1 | 1 | 34 | 30 | |
FC2 | 2 | 34 | 30 | |||
bridge_x_52b | FC1 | 1 | 35 | 31 | ||
FC2 | 2 | 35 | 31 | |||
Stack 3 | bridge_x_53a | FC1 | 1 | 36 | 32 | |
FC2 | 2 | 36 | 32 | |||
bridge_x_53b | FC1 | 1 | 37 | 33 | ||
FC2 | 2 | 37 | 33 | |||
Stack y | bridge_x_5ya | FC1 | 1 | 38 | 34 | |
FC2 | 2 | 38 | 34 | |||
bridge_x_5yb | FC1 | 1 | 39 | 35 | ||
FC2 | 2 | 39 | 35 | |||
Note Additional bridges can be cabled to ports 36 to 39 in DB620S and DB630S switches. |
Brocade port usage for ISLs in a MetroCluster configuration running ONTAP 9.4 or later
The following table shows ISL port usage for the Brocade switches.
Switch model | ISL port | Switch port |
---|---|---|
Lenovo B6505 FC SAN switch | ISL port 1 | 20 |
ISL port 2 | 21 | |
ISL port 3 | 22 | |
ISL port 4 | 23 | |
Lenovo B6510 | ISL port 1 | 40 |
ISL port 2 | 41 | |
ISL port 3 | 42 | |
ISL port 4 | 43 | |
ISL port 5 | 44 | |
ISL port 6 | 45 | |
ISL port 7 | 46 | |
ISL port 8 | 47 | |
Brocade G610 | ISL port 1 | 20 |
ISL port 2 | 21 | |
ISL port 3 | 22 | |
ISL port 4 | 23 | |
Lenovo ThinkSystem DB620S 32G FC SAN switch and Lenovo ThinkSystem DB630S 32G FC SAN switch | ISL port 1 | 40 |
ISL port 2 | 41 | |
ISL port 3 | 42 | |
ISL port 4 | 43 | |
ISL port 5 | 44 | |
ISL port 6 | 45 | |
ISL port 7 | 46 | |
ISL port 8 | 47 |