Skip to main content

Updating zoning when adding FibreBridge 7600N bridge to a configuration

The zoning must be changed when you are replacing FibreBridge 6500N bridges with FibreBridge 7600N bridge and using both FC ports on the FibreBridge 7600N bridge. Each zone can have no more than four initiator ports.

About this task

  • FibreBridge 7600N bridges are supported in ONTAP 9.6 and later.

  • The specific zoning in this task is for ONTAP 9.4 and later.

  • The zoning changes are required to avoid issues with ONTAP, which requires that no more than four FC initiator ports can have a path to a disk.

    After recabling to consolidate the shelves, the existing zoning would result in each disk being reachable by eight FC ports. You must change the zoning to reduce the initiator ports in each zone to four.

Update the storage zones for the FC switches by removing half of the initiator ports from each existing zone and creating new zones for the FibreBridge 7600N FC2 ports.

The zones for the new FC2 ports will contain the initiator ports removed from the existing zones.

The FC switch section of the Fabric-attached MetroCluster Installation and Configuration Guide contains details about the zoning commands.

Fabric-attached MetroCluster installation and configuration