FQXSPMA0012M : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the event log of system management module and xClarity Controller (XCC) for any fan- or cooling-related issues.
 - Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
 - Make sure that the room temperature is within operating specifications.
 - Make sure that the DIMM baffles are in place correctly.
 - If the problem remains and no other DIMMs have the same indication, replace the DIMM.
 
Give documentation feedback