Follow instructions in this section to remove and install supporting mounting configurations.

ThinkEdge SE360 V2 node is designed to support the following mounting options:

  • Desktop mount: The node is oriented horizontally with rubber feet installed at the bottom side. For the locations and replacement of rubber feet, see Rubber feet replacement.

  • Rack mount: Up to two nodes can be installed to an enclosure, and the enclosure can be installed to the rack. See Rack mount configuration.

  • Wall mount/ceiling mount: With node sleeve, the node can be mounted on the wall or the ceiling. See Wall mount/ceiling mount configuration.

  • DIN-rail mount: With node sleeve and DIN rail clips, the node can be mounted on a DIN rail. See DIN rail configuration.

Important
The mounting options of SE360 V2 support different system configuration. For proper operation, see the following table for the supported configurations:
Table 1. Supported configurations of SE360 V2 mounting options
 Desktop mountRack mountWall mount/ceiling mountDIN-rail mount
  • Wireless module
 
Electrical input
  • 300W external power adapter*
   
  • DC power source input
  • AC power source input
System fan
  • Front-to-rear air flow direction
  
  • Rear-to-front air flow direction
 
Optional components enabling dust filter measurement feature**

The following components are supported only when fans with rear-to-front air flow direction are installed:

  • Air flow sensor board
 
  • Rear dust filter
 
*When one or two 300W external power adapters are installed, keep ambient temperature lower than 40°C, and the following configuration is required:
  • 8 core processor
  • Four memory modules
  • Up to one ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU
  • Up to two 7mm SATA drives
  • Up to two M.2 NVMe boot drives installed on 1GbE I/O module board
  • Desktop mount is supported

**With air flow sensor board installed, SE360 V2 BMC supports dust filter measurement feature to check the status of the rear dust filter. See Set dust filter measurement for more information.