Skip to main content

FQXSPCA0009M : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0494

SNMP Trap ID

0

Automatically Notify Support

No

User Action

Complete the following steps:

  1. Check XClarity Controller GUI for any fan or cooling-related issues or power-related issues.
  2. Ensure the room temperature is within operating specifications.
  3. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place, clean, and correctly installed.
  4. Make sure the heat sink and GPU fillers in air baffle are installed corresponding to the system configuration.
  5. Replace the dust filter in the security bezel if applicable.
  6. Please contact Lenovo support.