FQXSPCA0019N : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps:
- Check XClarity Controller GUI for any fan or cooling-related issues or power-related issues.
- Ensure the room temperature is within operating specifications.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place, clean, and correctly installed.
- Make sure the heat sink and GPU fillers in air baffle are installed corresponding to the system configuration.
- Replace the dust filter in the security bezel if applicable.
- Please contact Lenovo support.