Skip to main content

FQXSPCA0019N : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0524

SNMP Trap ID

0

Automatically Notify Support

No

User Action

Complete the following steps:

  1. Check XClarity Controller GUI for any fan or cooling-related issues or power-related issues.
  2. Ensure the room temperature is within operating specifications.
  3. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place, clean, and correctly installed.
  4. Make sure the heat sink and GPU fillers in air baffle are installed corresponding to the system configuration.
  5. Replace the dust filter in the security bezel if applicable.
  6. Please contact Lenovo support.