LEDs on Firmware and Root of Trust Security Module

See this topic for the light-emitting diodes (LEDs) on the Firmware and Root of Trust Security Module (Firmware and RoT Security Module).

Note
Some security modules that are installed in the server might not come with LEDs.
Figure 1. LEDs on Firmware and RoT Security Module
Firmware and RoT Security Module LEDs

1 AP0 LED (Green)2 AP1 LED (Green)3 Fatal Error LED (Amber)
Table 1. RoT LEDs description
ScenarioAP0 LEDAP1 LEDFatal Error LEDFPGA heartbeat LEDnoteXCC heartbeat LEDnoteActions
RoT security module fatal firmware failureOffOffOnN/AN/A

Replace the Firmware and RoT Security Module.

BlinkingN/AOnN/AN/A

Replace the Firmware and RoT Security Module.

BlinkingN/AOnOnN/A

Replace the Firmware and RoT Security Module.

No system power (FPGA heartbeat LED off)OffOffOffOffOffIf AC power is on, but the system board does not have power, then:
  1. Check the power supply units (PSU) or power distribution board (PDB). If there is any PSU or PDB error, replace the defective PSU or PDB.

  2. If the PSU or PDB is good, replace the system board (see System board replacement (trained technician only)).

XCC firmware recoverable errorBlinkingN/AOffN/AN/A

Information only. No action is required.

XCC firmware is recovered from errorBlinkingN/AOffN/AN/A

Information only. No action is required.

UEFI firmware authentication failureN/ABlinkingOffN/AN/A

Information only. No action is required.

UEFI firmware is recovered from authentication failureN/AOnOffN/AN/A

Information only. No action is required.

System is OK (FPGA heartbeat LED is on)OnOnOffOnOn

Information only. No action is required.

Note
For locations of the FPGA LED and XCC heartbeat LED, see System-board LEDs.