CableFromTo
1 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 1
HBA/RAID adapter installed in PCIe slot 4:
  • Gen 3: C0C1

  • Gen 4: C0

2 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 2
HBA/RAID adapter installed in PCIe slot 1:
  • Gen 3: C0C1

  • Gen 4: C0

3 Power cablePower connector 1 on the backplaneBackplane 1 power connector on the system board
4 Power cablePower connector 2 on the backplaneBackplane 2 power connector on the system board
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 2. Cable routing for server models with sixteen 2.5-inch hot-swap drives, 8i adapters, and serial port module
Cable routing for server models with sixteen 2.5-inch hot-swap drives, 8i adapters, and serial port module

CableFromTo
1 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 1
HBA/RAID adapter installed in PCIe slot 1:
  • Gen 3: C0C1

  • Gen 4: C0

2 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 2
HBA/RAID adapter installed in PCIe slot 2:
  • Gen 3: C0C1

  • Gen 4: C0

3 Power cablePower connector 1 on the backplaneBackplane 1 power connector on the system board
4 Power cablePower connector 2 on the backplaneBackplane 2 power connector on the system board
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 3. Cable routing for server models with sixteen 2.5-inch hot-swap drives and 16i adapter
Cable routing for server models with sixteen 2.5-inch hot-swap drives and 16i adapter

CableFromTo
1 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 1
HBA/RAID adapter installed in PCIe slot 4:
  • Gen 3: C0C1

  • Gen 4: C0

2 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 2
HBA/RAID adapter installed in PCIe slot 4:
  • Gen 3: C2C3

  • Gen 4: C1

3 Power cablePower connector 1 on the backplaneBackplane 1 power connector on the system board
4 Power cablePower connector 2 on the backplaneBackplane 2 power connector on the system board
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 4. Cable routing for server models with sixteen 2.5-inch hot-swap drives, 16i adapter, and serial port module
Cable routing for server models with sixteen 2.5-inch hot-swap drives, 16i adapter, and serial port module

CableFromTo
1 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 1
HBA/RAID adapter installed in PCIe slot 1:
  • Gen 3: C0C1

  • Gen 4: C0

2 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane 2
HBA/RAID adapter installed in PCIe slot 1:
  • Gen 3: C2C3

  • Gen 4: C1

3 Power cablePower connector 1 on the backplaneBackplane power connector 1 on the system board
4 Power cablePower connector 2 on the backplaneBackplane power connector 2 on the system board
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).