Server models with sixteen 2.5-inch hot-swap drives
Use this section to understand the cable routing for server models with sixteen 2.5-inch hot-swap drives.
Figure 1. Cable routing for server models with sixteen 2.5-inch hot-swap drives and two 8i adapters
Cable | From | To |
---|---|---|
1 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 1 | HBA/RAID adapter installed in PCIe slot 4:
|
2 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 2 | HBA/RAID adapter installed in PCIe slot 1:
|
3 Power cable | Power connector 1 on the backplane | Backplane 1 power connector on the system board |
4 Power cable | Power connector 2 on the backplane | Backplane 2 power connector on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 2. Cable routing for server models with sixteen 2.5-inch hot-swap drives, 8i adapters, and serial port module
Cable | From | To |
---|---|---|
1 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 1 | HBA/RAID adapter installed in PCIe slot 1:
|
2 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 2 | HBA/RAID adapter installed in PCIe slot 2:
|
3 Power cable | Power connector 1 on the backplane | Backplane 1 power connector on the system board |
4 Power cable | Power connector 2 on the backplane | Backplane 2 power connector on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 3. Cable routing for server models with sixteen 2.5-inch hot-swap drives and 16i adapter
Cable | From | To |
---|---|---|
1 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 1 | HBA/RAID adapter installed in PCIe slot 4:
|
2 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 2 | HBA/RAID adapter installed in PCIe slot 4:
|
3 Power cable | Power connector 1 on the backplane | Backplane 1 power connector on the system board |
4 Power cable | Power connector 2 on the backplane | Backplane 2 power connector on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 4. Cable routing for server models with sixteen 2.5-inch hot-swap drives, 16i adapter, and serial port module
Cable | From | To |
---|---|---|
1 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 1 | HBA/RAID adapter installed in PCIe slot 1:
|
2 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane 2 | HBA/RAID adapter installed in PCIe slot 1:
|
3 Power cable | Power connector 1 on the backplane | Backplane power connector 1 on the system board |
4 Power cable | Power connector 2 on the backplane | Backplane power connector 2 on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Give documentation feedback