Server models with eight 2.5-inch hot-swap drives
Use this section to understand the cable routing for server models with eight 2.5-inch hot-swap drives.
Note
Both 8i and 16i RAID adapters are supported in this configuration.
Figure 1. Cable routing for server models with eight 2.5-inch hot-swap drives
Cable | From | To |
---|---|---|
1 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane | HBA/RAID adapter installed in PCIe slot 4:
|
2 Power cable | Power connector on the backplane | Backplane power connector 1 on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Figure 2. Cable routing for server models with eight 2.5-inch hot-swap drives and serial port module
Cable | From | To |
---|---|---|
1 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane | HBA/RAID adapter installed in PCIe slot 1:
|
2 Power cable | Power connector on the backplane | Backplane power connector 1 on the system board |
Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
Give documentation feedback