Skip to main content

Backplane for ten 2.5-inch hot-swap drives

Use this section to understand the connectors on the backplane and the internal cable routing for server models with ten 2.5-inch hot-swap drives.

Figure 1. Connectors on the backplane for ten 2.5-inch hot-swap drives
Connectors on the backplane for ten 2.5-inch hot-swap drives

1 SAS 2 connector2 SAS 1 connector3 Power connector4 SAS 0 connector
5 NVMe 1 connector6 NVMe 0 connector7 NVMe 3 connector8 NVMe 2 connector

Server models with six 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, and one 16i RAID adapter

Note
NVMe drives are only supported in drive bays 6–9.
Figure 2. Cable routing for server models with six 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, and one 16i RAID adapter
Cable routing for server models with ten 2.5-inch hot-swap drives

CableFromTo
1 Power cablePower connector on the backplaneBackplane power connector 1 and backplane power connector 2 on the system board
2 NVMe signal cableNVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on the backplaneNVMe 0-1 connector and NVMe 2-3 connector on the system board
3 SAS signal cable*SAS 0, SAS 1, and SAS 2 connectors on the backplane
HBA/RAID adapter:
  • Gen 3: C0C1C2

  • Gen 4: C0C1

Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay X40 RAID Cable Kit).

Server models with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, and one 8i RAID adapter

Note
NVMe drives are only supported in drive bays 6–9.
Figure 3. Cable routing for server models with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, and one 8i RAID adapter
Cable routing for server models with ten 2.5-inch hot-swap drives

CableFromTo
1 Power cablePower connector on the backplaneBackplane power connector 1 and backplane power connector 2 on the system board
2 NVMe signal cableNVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on the backplaneNVMe 0-1 connector and NVMe 2-3 connector on the system board
3 SAS signal cable*SAS 0 and SAS 1 connectors on the backplane
HBA/RAID adapter:
  • Gen 3: C0C1

  • Gen 4: C0

Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR530/SR570/SR630 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit).

Server models with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, one 16i RAID adapter, and one 1610-4P NVMe switch adapter

Note
  • NVMe drives are only supported in drive bays 6–9.

  • This configuration is supported in server models installed with one processor.

Figure 4. Cable routing for server models with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, one 16i RAID adapter in PCIe slot 1, and one 1610-4P NVMe switch adapter in PCIe slot 2
Cable routing for server models with ten 2.5-inch hot-swap drives

CableFromTo
1 Power cablePower connector on the backplaneBackplane power connector 1 and backplane power connector 2 on the system board
2 NVMe signal cableNVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on the backplaneC0, C1, C2, and C3 connectors on the NVMe switch adapter installed in PCIe slot 2
3 SAS signal cable*SAS 0, SAS 1 and SAS 2 connectors on the backplane
HBA/RAID adapter installed in PCIe slot 1:
  • Gen 3: C0C1C2

  • Gen 4: C0C1

Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay X40 RAID Cable Kit).

Server models with four 2.5-inch NVMe drives and no RAID adapter

Note
NVMe drives are only supported in drive bays 6–9.
Figure 5. Cable routing for server models with four 2.5-inch NVMe drives, and no RAID adapter
Cable routing for server models with ten 2.5-inch hot-swap drives

CableFromTo
1 Power cablePower connector on the backplaneBackplane power connector 1 and backplane power connector 2 on the system board
2 NVMe signal cableNVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on the backplaneNVMe 0-1 connector and NVMe 2-3 connector on the system board