Processor

Processor

Supports multi-core Intel Xeon processors, with integrated memory controller and Intel Mesh UPI (Ultra Path Interconnect) topology.

  • Up to two 4th Gen Intel Xeon scalable processors with the new LGA 4677-X socket

  • Up to 60 cores per socket

  • Up to 4 UPI links at up to 16 GT/s

  • Thermal Design Power (TDP): up to 350 watts

For a list of supported processors, see: Lenovo ServerProven website.

Memory

Memory

See Memory module installation rules and order for detailed information about memory configuration and setup.

  • Slots: 32 dual inline memory module (DIMM) connectors that support up to:

    • 32 DDR5 DIMMs

  • Memory module type:

    • TruDDR5 4800MHz RDIMM: 16 GB (1Rx8), 32 GB (2Rx8)

    • TruDDR5 4800MHz 10x4 RDIMM: 32 GB (1Rx4), 64 GB (2Rx4)

    • TruDDR5 4800MHz 9x4 RDIMM: 32 GB (1Rx4), 64 GB (2Rx4)

    • TruDDR5 4800MHz 3DS RDIMM: 128 GB (4Rx4), 256 GB (8Rx4)

  • Speed: Operating speed depends on processor model and UEFI settings.

    • 4800 MT/s for 1 DIMM per channel

    • 4400 MT/s for 2 DIMMs per channel

  • Minimum memory: 16 GB

  • Maximum memory: 8 TB: 32 x 256 GB 3DS RDIMMs

For a list of supported memory options, see Lenovo ServerProven website.

For technical rules for memory modules, see Memory module installation rules and order.

Internal drives

Internal drives
Front:
  • Up to four 3.5-inch hot-swap SAS/SATA drives

  • Up to four 3.5-inch hot-swap AnyBay (SAS/SATA/NVMe) drives

  • Up to four 2.5-inch hot-swap SAS/SATA drives

  • Up to four 2.5-inch hot-swap NVMe drives

  • Up to eight 2.5-inch hot-swap SAS/SATA drives

  • Up to six 2.5-inch hot-swap SAS/SATA and four 2.5-inch hot-swap AnyBay (SAS/SATA/NVMe) drives

  • Up to six 2.5-inch hot-swap SAS/SATA and two 2.5-inch hot-swap AnyBay (SAS/SATA/NVMe) and two 2.5-inch hot-swap NVMe drives

  • Up to ten 2.5-inch hot-swap SAS/SATA drives

  • Up to eight 2.5-inch hot-swap NVMe drives

  • Up to ten 2.5-inch hot-swap NVMe drives

  • Up to ten 2.5-inch hot-swap AnyBay (SAS/SATA/NVMe) drives

  • Up to 16 hot-swap EDSFF drives

Inside:
  • Up to two internal SATA or NVMe M.2 drives

Rear:
  • Up to two 2.5-inch hot-swap SAS/SATA or NVMe drives

  • Up to two 7mm hot-swap SATA or NVMe drives

Note
  • M.2 and 7mm drives are not supported at the same time.

  • If 256 GB DIMM is used, rear 2.5-inch drives are not supported.

Expansion slots

Expansion slots

Depending on the model, your server supports up to three PCIe slots in the rear and up to two PCIe slots in the front.

  • PCIe x16, low-profile

  • PCIe x16/x16, low-profile + low-profile

  • PCIe x16/x16, low profile + full-height

  • PCIe x16, full-height

Graphics processing unit (GPU)

Graphics processing unit (GPU)
Your server supports the following GPU:
  • Low-profile, half-length, single-wide:
    • NVIDIA® A2

Note
For GPU supporting rules, see Thermal rules.

Integrated functions and I/O connectors

Integrated functions and I/O connectors
  • Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities.
  • One XCC system management port on the rear to connect to a systems-management network. This RJ-45 connector is dedicated to the Lenovo XClarity Controller functions and runs at 1 GB speed.
  • A group of two or four Ethernet connectors on OCP module

  • Up to four USB 3.2 Gen1 (5 Gbps) ports:

    • Three on the rear of the server

    • (Optional) One on the front of the server1

  • One internal USB 3.2 Gen1 (5 Gbps) port

  • (Optional) One USB 2.0 port on the front of the server1

  • (Optional) External LCD diagnostics handset connector on the front of the server1

  • Up to two VGA connectors

    • One on the rear of the server

    • (Optional) One on the front of the server1

  • (Optional) One serial port connector on the rear of the server2

Note
  1. Available when the front I/O module is installed in the server.

  2. Available when the serial port cable is installed in the server.

Network

Network
  • OCP module

Note
The OCP module is an optional part. It is default to be installed in the rear and optional in the front of the server.

Rear button

Rear button
  • NMI button

RAID adapter

RAID adapter
Support the following RAID adapters:
  • ThinkSystem RAID 5350-8i PCIe 12Gb Adapter

  • ThinkSystem RAID 540-8i PCIe 12Gb Adapter

  • ThinkSystem RAID 540-16i PCIe 12Gb Adapter

  • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter

  • ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter

  • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter

  • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter (Tri-mode)

  • ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter

  • ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter (Tri-mode)

  • ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter

  • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter

  • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter (Tri-mode)

  • ThinkSystem RAID 5350-8i PCIe 12Gb Internal Adapter

  • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter

  • ThinkSystem RAID 9350-8i 2GB Flash PCIe Gen 4 12Gb Internal Adapter

  • ThinkSystem RAID 9350-16i 4GB Flash PCIe Gen 4 12Gb Internal Adapter

Host bus adapter

Host bus adapter
Support the following HBAs:
  • ThinkSystem 4350-8i SAS/SATA 12Gb HBA

  • ThinkSystem 4350-16i SAS/SATA 12Gb HBA

  • ThinkSystem 440-8i SAS/SATA 12Gb HBA

  • ThinkSystem 440-8e SAS/SATA 12Gb HBA

  • ThinkSystem 440-16i SAS/SATA 12Gb HBA

  • ThinkSystem 440-16e SAS/SATA 12Gb HBA

  • ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA

  • ThinkSystem QLogic 16Gb Enhanced Gen5 FC Single-port HBA

  • ThinkSystem QLogic 16Gb Enhanced Gen5 FC Dual-port HBA

  • ThinkSystem Emulex 16Gb Gen6 FC Single-port HBA

  • ThinkSystem Emulex 16Gb Gen6 FC Dual-port HBA

System fan

System fan
  • Supported fan types:

    • Standard fan 4056 (21000 RPM)

    • Performance fan 4056 (28000 RPM)

  • Fan redundancy: N+1 redundancy, one redundant fan rotor

    • One processor: six hot-swap dual-rotor system fans (one redundant fan rotor)

    • Two processors: eight hot-swap dual-rotor system fans (one redundant fan rotor)

Note

The redundant cooling by the fans in the server enables continued operation if one rotor of a fan fails.

If there is an OCP module installed, when the system is powered off but still plugged in to AC power, system fan 1 and fan 2 will continue to spin at a much lower speed. This is the system design to provide proper cooling for the OCP module.

Electrical input

Electrical input
One or two hot-swap power supply units for redundancy support:
Table 1. Electrical input for power supply units
Power supply100–127 V ac200–240 V ac240 V dc-48 V dc
750-watt 80 PLUS Platinum 
1100-watt 80 PLUS Platinum 
1800-watt 80 PLUS Platinum  
750-watt 80 PLUS Titanium  
1100-watt 80 PLUS Titanium  
1800-watt 80 PLUS Titanium  
1100-watt -48 V DC   
CAUTION
  • 240 V dc input is supported in Chinese Mainland ONLY.

  • Power supply with 240 V dc input cannot support hot plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.

Minimal configuration for debugging

Minimal configuration for debugging
  • One processor in processor socket 1

  • One memory module in slot 7

  • One power supply unit

  • One HDD/SSD drive, one M.2 drive, or one 7mm drive (if OS is needed for debugging)

  • Six system fans (with one processor)

Operating systems

Operating systems
Supported and certified operating systems:
  • Microsoft Windows Server

  • VMware ESXi

  • Red Hat Enterprise Linux

  • SUSE Linux Enterprise Server

  • Canonical Ubuntu

References: