FQXSPPW0135J : Invalid redundancy config, current PSU config doesn't support Non-redundant mode.
Invalid redundancy config, current PSU config doesn't support Non-redundant mode.
This message is for the use case when redundancy failed has asserted
Severity
Error
Alert Category
Warning - Redundant Power Supply
Serviceable
Yes
SNMP Trap ID
10
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check if the PSUs are installed correctly.
- Check if the PSUs are supported by the platform.
- If the problem persists, upgrade XCC, FPGA, and UEFI to the latest versions.
- If the problem persists, collect the service data logs.
- Contact Lenovo Support.
- Note: This event is reported if only one CRPS PSU is installed on the system because CRPS PSU only supports the redundant mode.