Перейти к основному содержимому

FQXSPPW0135J : Invalid redundancy config, current PSU config doesn't support Non-redundant mode.

Invalid redundancy config, current PSU config doesn't support Non-redundant mode.

This message is for the use case when redundancy failed has asserted

Severity

Error

Alert Category

Warning - Redundant Power Supply

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0901

SNMP Trap ID

10

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check if the PSUs are installed correctly.
  2. Check if the PSUs are supported by the platform.
  3. If the problem persists, upgrade XCC, FPGA, and UEFI to the latest versions.
  4. If the problem persists, collect the service data logs.
  5. Contact Lenovo Support.
  6. Note: This event is reported if only one CRPS PSU is installed on the system because CRPS PSU only supports the redundant mode.