FQXSPPW0104J : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:Sufficient.
Severity
Warning
Alert Category
Warning - Redundant Power Supply
Serviceable
Yes
SNMP Trap ID
10
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the PSU LED:
- If AC LED is not lit, check the power cord and input voltage.
- If DC LED is not lit, remove and then reinstall the power supply.
- If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
Give documentation feedback