FQXSPPW0079N : Sensor [SensorElementName] has transitioned to non-recoverable.
Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
No
User Action
Complete the following steps:
- If the sensor is DIMM {N} PMIC.
- Power off the system and remove A/C power.
- Reseat the DIMM in the slot specified by the event message. Restore A/C power and power on the system.
- If the problem persist collect Service Data log.
- Contact Lenovo Support.
- If the sensor is not DIMM {N} PMIC.
- AC cycle the system.
- If the problem persist collect Service Data log.
- Contact Lenovo Support.
Give documentation feedback