Technical rules for HBA/RAID adapters
HBA/RAID adapters | Maximum supported | Slot selection priority | Suggested priority (between adapters) | Super capacitor |
---|---|---|---|---|
ThinkSystem 430-8i SAS/SATA 12Gb HBA | 4 | 9, 1, 2, 3, 4, 5, 6 | 16 | No |
ThinkSystem 430-16i SAS/SATA 12Gb HBA | 2 | 1, 2, 3, 4, 5, 6 | 16 | No |
ThinkSystem 430-8e SAS/SATA 12Gb HBA | 5 | 1, 2, 4, 5, 7 | 19 | No |
ThinkSystem 430-16e SAS/SATA 12Gb HBA | 5 | 1, 2, 4, 5, 7 | 19 | No |
ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA | 4 | 9, 1, 2, 3, 4, 5, 6 | 16 | No |
ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA | 2 | 1, 2, 3, 4, 5, 6 | 16 | No |
ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA | 5 | 1, 2, 4, 5, 7 | 19 | No |
ThinkSystem 440-16e 12Gb HBA | 5 | 1, 2, 4, 5, 7 | 19 | No |
ThinkSystem RAID 530-8i PCIe 12Gb Adapter | 4 | 9, 1, 2, 3, 4, 5, 6 | 15 | No |
ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter | 4 | 9, 1, 2, 3, 4, 5, 6 | 15 | No |
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | 3 | 9, 1, 2, 3, 4, 5, 6 | 14 | No |
ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter | 3 | 9, 1, 2, 3, 4, 5, 6 | 13 | Yes |
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | 3 | 9, 1, 2, 3, 4, 5, 6 | 11 | Yes |
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | 1 | 1, 2, 3, 4, 5, 6 | 12 | Yes |
ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter | 1 | 1, 2, 3, 4, 5, 6 | 12 | Yes |
ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter | 1 | 1, 2, 3, 4, 5 | 10 | Yes |
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | 4 | 1, 2, 4, 5, 7 | 19 | Yes |
ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter | 3 | 9, 1, 2, 3, 4, 5, 6 | 11 | Yes |
ThinkSystem RAID 940-16i 4GB Flash PCIe 12Gb Adapter | 1 | 1, 2, 3, 4, 5, 6 | 12 | Yes |
ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter | 1 | 1, 2, 3, 4, 5 | 10 | Yes |
ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter | 4 | 1, 2, 4, 5, 7 | 19 | Yes |
ThinkSystem 810-4P NVMe Switch Adapter | 4 | 1, 4, 5, 6 | 4 | No |
ThinkSystem 1610-4P NVMe Switch Adapter | 3 | 1, 4, 5 | 3 | No |
ThinkSystem 1611-8P PCIe Gen4 Switch Adapter | 2 | 1, 5 | 3 | No |
If you plan to use the RAID 530-8i adapter in the server, it must have firmware 50.3.0-1032 or later applied before it can be used in the server. If the adapter you plan to use has older firmware, it must first be upgraded by installing it in a supported server and upgrading the firmware there. For more information, see https://datacentersupport.lenovo.com/us/zh/solutions/ht509177.
The RAID 530-8i adapter cannot be mixed with the RAID 730-8i 1G adapter.
The RAID 540-8i adapter can be mixed with other x40 series RAID/HBA adapters.
The RAID 730-8i-1G adapter is not available for North America.
The RAID 730-8i 2G adapter cannot be mixed with the RAID 730-8i 1G adapter or RAID 930-8i adapter.
If the rear 3.5-inch drive cage is installed, the RAID 930-24i adapter can only be installed in slot 3. If the rear 2.5-inch drive cage is installed, the RAID 930-24i adapter can only be installed in slot 1 or 2.
The RAID 940 adapters can be mixed with the 440-8i or 440-16i HBA adapters.
The RAID 940/440 adapters cannot be mixed with the RAID 930/730/530/430 adapters.
Oversubscription may exist in some configurations with NVMe switch adapters. For details, see: Internal storage.
When there are more than 16 NVMe SSDs, switch adapters must be selected.
External RAID adapters are not supported in slots 3, 6 or 8.
If a RAID 730-8i 1 GB/2 GB adapter is installed, ThinkSystem 2.5"/ 3.5" PM1653 Read Intensive SAS 24 Gb SSDs and ThinkSystem 2.5" PM1655 Mixed Use SAS 24 Gb SSDs cannot be installed.
The HBA 430/440 adapters cannot be installed whenThinkSystem 2.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD or ThinkSystem 3.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD is installed.