Skip to main content

Drive bay configurations and requirements

This topic describes the drive bay configurations supported by the server and the requirements for hardware configurations.

The server supports hot-swap drives in three drive zones:
  • Front bays: up to 12 x 3.5-inch or 24 x 2.5-inch hot-swap bays

  • Middle (internal) bays: up to 4 x 3.5-inch or 8 x 2.5-inch hot-swap bays

  • Rear bays: up to 4 x 3.5-inch or 4 x 2.5-inch hot-swap bays

Note

VMware ESXi does not support ThinkSystem 2.5 U.3 6500 ION 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD.

Depending on the server chassis and hardware configurations, the server supports different drive bay combinations.

Chassis with 3.5-inch front drive bays

The following table shows the supported drive bay combinations for the chassis with 3.5-inch front drive bays.

Note
  • NVMe drives are only supported in the front drive bays (bays 8–11), using the AnyBay backplane (which offers 4 x NVMe capable drive bays).

  • When the front drive bays are 3.5-inch bays, the middle drive bays are also 3.5-inch bays. However, the rear drive bays can be either 2.5-inch SAS/SATA or 3.5-inch SAS/SATA bays.

  • When the front SAS/SATA backplane is connected to PCIe connectors on the system board, only SATA drives are supported. No SAS drives are supported.

  • For the middle/rear drive cage with an NVMe backplane, only 7 mm NVMe drives (installed in the 15 mm-height drive trays) are supported. The 15 mm drives are not supported.

  • To support a middle drive cage:
    • Performance fans (speed of 29000 RPM) must be installed.

    • The processor TDP must be lower than or equal to 155 watts.

    • The ambient temperature must be lower than or equal to 35°C (95°F).

    • All empty memory slots must be covered with a memory module filler or new memory module to ensure optimal air flow.

  • To support a rear drive cage:
    • Performance fans (speed of 29000 RPM) must be installed.

    • The processor TDP must be lower than or equal to 225 watts.

    • The ambient temperature must be lower than or equal to 35°C (95°F).

3.5": 3.5-inch; 2.5": 2.5-inch
ConfigTotal drivesFront bays (3.5")Mid bays (3.5")Rear bays (3.5" or 2.5")
SAS/SATAAnyBaySAS/SATA3.5" SAS/SATA2.5" SAS/SATA
3.5-inch chassis – SAS/SATA drives only
A880000
B12120000
C16120040
D16120004
E20120440
F20120404
3.5-inch chassis – SAS/SATA and AnyBay drives
G1284000
H1684040
I1684004
J2084440
K2084404
3.5-inch chassis – no backplanes, no drives
L012 (with drive fillers)0000

Chassis with 2.5-inch front drive bays

The following table shows the supported drive combinations for the chassis with 2.5-inch front drive bays.
Note
  • With the 2.5-inch chassis, all drive bays are 2.5-inch bays. No 3.5-inch drives are supported.

  • Middle drive bays and rear drive bays cannot be used concurrently.

  • When the front SAS/SATA backplane is connected to PCIe connectors on the system board, only SATA drives are supported. No SAS drives are supported.

  • For the middle/rear drive cage with an NVMe backplane, only 7 mm NVMe drives (installed in the 15 mm-height drive trays) are supported. The 15 mm drives are not supported.

  • To support a middle drive cage:
    • Performance fans (speed of 29000 RPM) must be installed.

    • The processor TDP must be lower than or equal to 155 watts.

    • The ambient temperature must be lower than or equal to 35°C (95°F).

      Note that the ambient temperature must be lower than or equal to 30°C (86°F) for the server model with 24 NVMe front drive bays.

    • All empty memory slots must be covered with a memory module filler or new memory module to ensure optimal air flow.

  • To support a rear drive cage:
    • Performance fans (speed of 29000 RPM) must be installed.

    • The processor TDP must be lower than or equal to 225 watts.

    • The ambient temperature must be lower than or equal to 35°C (95°F).

3.5": 3.5-inch; 2.5": 2.5-inch
ConfigTotal drivesFront bays (2.5")Mid bays (2.5")Rear bays (2.5")
SAS/SATANVMeSAS/SATANVMeSAS/SATANVMe
2.5-inch chassis – SAS/SATA drives only
A8800000
B161600000
C201600040
D242400000
E282400040
F322408000
2.5-inch chassis – SAS/SATA and NVMe drives in the front bays
G16880000
H20880040
I241680000
J281680040
K321688000
2.5-inch chassis – only NVMe drives in the front bays
L8080000
M160160000
N200160040
O200160004
P240240000
Q280240040
R280240004
S320248000
T320240800
2.5-inch chassis – no backplanes, no drives
U024 (with drive fillers)00000