Skip to main content

Specifications

The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 1. Server specifications
SpecificationDescription
Dimension
  • 2U

  • Height: 86.5 mm (3.4 inches)

  • Width:
    • With rack latches: 482.0 mm (19.0 inches)

    • Without rack latches: 444.6 mm (17.5 inches)

  • Depth: 764.7 mm (30.1 inches)

    Note
    The depth is measured with rack latches installed, but without the security bezel installed.
Weight

Up to 35.4 kg (78.0 lb), depending on the server configuration

Processor (depending on the model)
  • One AMD® EPYCTM 7002 or 7003 processor

  • Designed for Land Grid Array (LGA) 4094 (SP3) socket

  • Scalable up to 64 cores

  • Thermal Design Power (TDP): up to 280 watts

For technical rules about processors, see Technical rules for processor and heat sink.

For a list of supported processors, see: Lenovo ServerProven website

Operating systemsSupported and certified operating systems:
  • Microsoft Windows Server

  • VMware ESXi

  • Red Hat Enterprise Linux

  • SUSE Linux Enterprise Server

  • Win10 Pro and Win11 Pro for Workstations

References:
Memory
  • Slots: 16 DIMM slots

  • Minimum: 8 GB

  • Maximum: 2 TB

  • Type (depending on the model):

    • TruDDR4 2933, single-rank or dual-rank, 8 GB/16 GB/32 GB/64 GB RDIMM

    • TruDDR4 3200, dual-rank, 16 GB/32 GB/64 GB RDIMM

    • TruDDR4 2933, quad-rank, 128 GB 3DS RDIMM

    • TruDDR4 3200, quad-rank, 128 GB 3DS RDIMM

Note
Operating speed and total memory capacity depend on the processor model and UEFI settings.

For installation rules about memory modules, see Memory module installation rules.

For a list of supported memory modules, see: Lenovo ServerProven website

Internal drives
The server supports:
  • Up to twenty 3.5-inch SAS/SATA drives

    Or up to 16 SAS/SATA drives and 4 NVMe/SAS/SATA drives (NVMe drives supported only in front drive bays 8–11)

  • Up to thirty-two 2.5-inch SAS/SATA/NVMe drives

  • Up to two internal M.2 drives

The supported drives vary by models. For detailed information, see Drive bay configurations and requirements.

Expansion slots
  • Up to nine PCIe slots: eight PCIe slots in the rear and one internal PCIe slot

  • One OCP 3.0 slot

For detailed information, see Rear view.

Input/Output (I/O) features
  • Front panel:

    • One VGA connector (optional)

    • Two USB 3.2 Gen 1 (5 Gbps) connectors

  • Rear panel:

    • One serial port

    • One VGA connector

    • Two USB 3.2 Gen 1 (5 Gbps) connectors

    • One RJ-45 BMC management connector

    • Two or four Ethernet connectors on the OCP 3.0 Ethernet adapter (optional)

Graphics processing unit (GPU)
Your server supports the following GPUs or processing adapters:
  • Half-length, low-profile, single-wide GPUs:
    • ThinkSystem NVIDIA Quardo P620 2GB PCIe Active GPU

    • ThinkSystem NVIDIA Tesla T4 16GB PCIe Passive GPU

    • ThinkSystem NVIDIA A2 16GB Gen4 Passive GPU

    • ThinkSystem NVIDIA Quadro RTX A2000 12GB PCIe Active GPU

  • Full-length, full-height, double-wide GPUs:
    • ThinkSystem NVIDIA Tesla V100 32 GB PCIe Passive GPU

    • ThinkSystem NVIDIA Tesla V100 16 GB PCIe Passive GPU

    • ThinkSystem NVIDIA Tesla V100S 32GB PCIe Passive GPU

    • ThinkSystem NVIDIA A100 40GB PCIe Gen4 Passive GPU

    • ThinkSystem NVIDIA A100 80GB PCIe Gen4 Passive GPU

    • ThinkSystem NVIDIA A30 24GB PCIe Gen4 Passive GPU

    • ThinkSystem NVIDIA A40 48GB PCIe Gen4 Passive GPU

    • ThinkSystem AMD Instinct MI210 PCIe Gen4 Passive Accelerator

    • ThinkSystem NVIDIA Quadro RTX A4500 20GB PCIe Active GPU

    • ThinkSystem NVIDIA Quadro RTX A6000 48GB PCIe Active GPU

For technical rules for GPU, see Technical rules for GPU adapters.

HBA/RAID adapters
  • Support the following HBA adapters for JBOD mode:

    • HBA 430-8i, 430-16i, 430-8e or 430-16e SAS/SATA adapter

    • HBA 440-8i, 440-16i, 440-8e, or 440-16e SAS/SATA adapter

  • Support the following RAID adapters for JBOD mode and RAID levels 0, 1, 5, 10, and 50
    • RAID 530-8i PCIe adapter

    • RAID 540-8i PCIe adapter

    • RAID 730-8i 1G Cache PCIe adapter

    • RAID 730-8i 2G Flash PCIe adapter

    • RAID 930-8i, 930-16i, 930-24i or 930-8e Flash PCIe adapter

    • RAID 940-8i, 940-16i, 940-32i or 940-8e Flash PCIe adapter

  • Support the following controllers for rich NVMe configurations:

    • 810-4P NVMe switch adapter

    • 1610-4P NVMe switch adapter

    • 1611-8P NVMe switch adapter

For technical rules for storage controller adapters, see Technical rules for HBA/RAID adapters.

System fans
  • Up to six hot-swap system fans (N+1 redundancy, one redundant fan)

  • Two types of fans supported:
    • ThinkSystem SR655 2U fan module (standard fan)

    • ThinkSystem SR655 performance fan module (speed of 29000 RPM)

Note
If there is an OCP 3.0 Ethernet adapter installed, when the system is powered off but still plugged in to ac power, fans 5 and fan 6 will continue to spin at a much lower speed. This is the system design to provide proper cooling for the OCP 3.0 Ethernet adapter.

For technical rules for system fans, see Technical rules for system fans.

Electrical input

The server supports up to two hot-swap power supplies for redundancy.

Power supply100–127 V ac200–240 V ac240 V dc*-48 V dc
(50–60 Hz)(50–60 Hz)  
550-watt 80 PLUS Platinum×
750-watt 80 PLUS Platinum×
750-watt 80 PLUS Titanium××
1100-watt 80 PLUS Platinum×
1600-watt 80 PLUS Platinum××
2000-watt 80 PLUS Platinum××
1100-watt -48V DC×××
CAUTION
240 V dc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY. Power supply with 240 V dc input cannot support hot plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.
Minimal configuration for debugging
  • One processor
  • One DIMM in slot 1
  • One power supply
  • One HDD or M.2 drive (if OS is needed for debugging)
  • System fans:
    • Six system fans if an M.2 drive is installed

    • Five system fans (fan 2 to fan 6) if no M.2 drive is installed

Acoustical noise emissions

The declared acoustic noise levels are based on below configurations, which may change depending on configurations and conditions:

Config.TypicalStorage richGPU rich
CPU1 x 155 W1 x 155 W1 x 155 W
DIMM16 x 32GB16 x 64 GB16 x 64 GB
Ethernet10 GbE BASE-T 2-port PCIe10 GbE BASE-T 4-port PCIe10 GbE BASE-T 4-port PCIe
PSU2 x 750 W2 x 750 W2 x 1600 W
RAID930-16i RAID930-24i RAID930-8i RAID
Drive16 x 2.5'' HDD20 x 3.5'' HDD8 x 2.5'' HDD
GPUNANA2 x V100 GPU
Sound power levels (LWA,m)
StatusTypicalStorage richGPU rich
Idling6.2 Bel7.0 Bel7.0 Bel
Operating6.2 Bel7.2 Bel8.5 Bel
Sound pressure level (LpA,m)
StatusTypicalStorage richGPU rich
Idling46 dBA54 dBA54 dBA
Operating47 dBA56 dBA69 dBA
Note
  • These sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.

  • Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.

Environment
The server is supported in the following environment:
Note
This server is designed for standard data center environment and recommended to be placed in industrial data center.
  • Air temperature:

    • Operating: ASHRAE class A2: 10–35°C (50–95°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 300 m (984 ft) of altitude increase.

    • Server off: 5–45°C (41–113°F)

    • Shipping or storage: -40–60°C (-40–140°F)

  • Maximum altitude: 3050 m (10 000 ft)

  • Relative humidity (non-condensing):

    • Operating: ASHRAE class A2: 8%–80%; maximum dew point: 21°C (70°F)

    • Shipping or storage: 8%–90%

  • Particulate contamination
    Attention
    Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.

Your server complies with ASHRAE class A2 specifications.

Depending on the hardware configuration, some server models comply with ASHRAE class A3 and class A4 specifications, see ASHRAE class compliance information.