FQXSPCA0011N : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has asserted.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps:
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers/air-baffles are in place,clean, and correctly installed.
- Ensure the room, water temperature and water flow rate are within server environmental specification to adjust the temperature.
- Ensure GPU/NVswitch cold plates are securely installed.
- If the problem issue still exist, check XCC Web GUI to check the temperature value is still higher than system spec.
- Please contact Lenovo support.
- If the message persists more than 24 hours after GPU is replaced, contact Lenovo service
Give documentation feedback