FQXSPCA0019N : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
"Complete the following steps:
- Check the event log of XClarity Controller for any fan or cooling-related issues or power-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place, clean, and correctly installed.
- Ensure CPU/GPU/NVswitch cold plates are securely installed.
- Make sure that the room temperature, water temperature and water flow rate is within operating specifications.
- If the message persists more than 24 hours after GPU is replaced, contact Lenovo service"
Give documentation feedback