Passa al contenuto principale

FQXSPSD0006L : Array [ComputerSystemElementName] has failed.

Array [ComputerSystemElementName] has failed.

This message is for the use case when an implementation has detected that an Array Failed.

Severity

Error

Alert Category

Critical - Hard Disk drive

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0176

SNMP Trap ID

5

Automatically Notify Support

Yes

User Action

Complete the following steps until the problem is solved:

  1. Review PD Steps by confirming the RAID array is in failed state.
  2. Note: Notify the customer that the data has been lost and a new RAID volume will have to be created.
  3. Replace the affected disk drive(s) that is indicated by a fault LED or the system event log.
  4. Clear RAID configuration and create a new RAID array.
  5. Restore data from backup.
  6. If problem persists, escalate to next level of support.