Skip to main content

With two processors

Follow the instructions in this section to learn how do cable routing for combinations with one AnyBay backplane and two processors.

One backplane

One AnyBay backplane

On-board connector





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1845 mmOn-board1 0-1, 2-3670 mmPCIe 1 (on-board)
   2 4-5, 6-7910 mmPCIe 2 (on-board)

8i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1665 mmC0 (8i)1 0-1, 2-3670 mmPCIe 1 (on-board)
   2 4-5, 6-7910 mmPCIe 2 (on-board)

16i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1
  • Gen3: 665 mm
  • Gen4: 690 mm
C0 (16i)1 0-1, 2-3670 mmPCIe 1 (on-board)
   2 4-5, 6-7910 mmPCIe 2 (on-board)

Two backplanes

One AnyBay and one SAS/SATA backplane

16i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1665 mmC0 (16i)1 0-1, 2-3670 mmPCIe 1 (on-board)
2860 mmC1 (16i)2 4-5, 6-7910 mmPCIe 2 (on-board)

Three backplanes

One AnyBay and two SAS/SATA backplanes

On-board connector + 16i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1845 mmOn-board1 0-1, 2-3670 mmPCIe 1 (on-board)
2860 mmC0 (16i)2 4-5, 6-7910 mmPCIe 2 (on-board)
31000 mmC1 (16i)   

8i + 16i RAID adapters





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1665 mmC0 (8i)1 0-1, 2-3670 mmPCIe 1 (on-board)
2860 mmC0 (16i)2 4-5, 6-7910 mmPCIe 2 (on-board)
31000 mmC1 (16i)   

32i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1860 mmC0 (32i)1 0-1, 2-3670 mmPCIe 1 (on-board)
2690 mmC1 (32i)2 4-5, 6-7910 mmPCIe 2 (on-board)
3665 mmC2 (32i)   

16i + 8i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1665 mmC0 (16i)1 0-1, 2-3670 mmPCIe 1 (on-board)
2860 mmC1 (16i)2 4-5, 6-7910 mmPCIe 2 (on-board)
31000 mmC0 (8i)