Skip to main content

Technical specifications

Summary of the technical specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.

Processor
Supports multi-core Intel Xeon processors, with integrated memory controller and Intel Mesh UPI (Ultra Path Interconnect) topology.
  • Up to four 4th Gen Intel Xeon scalable processors with minimal requirement of two installed on the system board assembly
  • Designed for LGA 4677 sockets
  • Scalable up to 60 cores
  • Supports 4 UPI links per processor supporting 12.8 GT/s, 14.4 GT/s and 16 GT/s speeds

For a list of supported processors, see Lenovo Data Center Support.

Memory

See Memory module installation rules and order for detailed information about memory configuration and setup.

  • 64 dual inline memory module (DIMM) slots that support up to 64 DRAM DIMMs
  • Memory module type:
    • TruDDR5 4800MHz RDIMM: 16 GB (1Rx8), 32 GB (1Rx4, 2Rx8), 64 GB (2Rx4), 96 GB (2Rx4)
    • TruDDR5 4800MHz Value RDIMM: 32 GB (1Rx4), 64 GB (2Rx4)
    • TruDDR5 4800MHz 3DS RDIMM: 128 GB (4Rx4), 256 GB (8Rx4)
  • Speed:
    Note
    Operating speed depends on processor model and UEFI settings.
    • 4800 MT/s for 1 DIMM per channel
    • 4400 MT/s for 2 DIMMs per channel
  • Minimum memory: 32 GB
  • Maximum memory: 16 TB

For a list of supported memory modules, see Lenovo ServerProven website.

M.2 Drive
The server support up to two internal M.2 drives with the following capacity:
  • SATA M.2 drive:
    • 128 GB
    • 240 GB
    • 480 GB
    • 960 GB
  • NVMe M.2 drive:
    • 480 GB
    • 960 GB
The following form factors are supported:
  • 42 mm (2242)
  • 60 mm (2260)
  • 80 mm (2280)
  • 110 mm (22110)

For a list of supported M.2 drives, see Lenovo ServerProven website.

Storage expansion
The server model with 2.5-inch drives supports:
  • Up to twenty-four 2.5-inch hot-swap SAS/SATA/NVMe drives
  • Up to two 7mm SATA/NVMe drives
Note
  • When an M.2 backplane is installed and connected to the NVMe 11 connector, the maximum number of supported NVMe drives is twenty-two drives.
  • NVMe drives support VROC.
  • Tri-mode adapters support RAID with U.3 drives.
  • When the following components are installed in the system, the maximum number of supported drives is sixteen.
    • DRAM DIMMs with capacity larger than 128 GB
    • ConnectX-7 NDR200 QSFP 2-port adapter or ConnectX-7 NDR400 QSFP 1-port adapter with Active Optical Cable

For a list of supported drives, see Lenovo ServerProven website.

Expansion slots
  • Up to twelve PCIe slots (depending on the server model):
    • Slot 3-14
  • Up to two OCP slots:
    • Slot 1-2
Note
When a ThinkSystem Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter is installed, no other OCP module can be installed.
Graphics processing unit (GPU)
The server supports the following GPU configurations:
  • Up to four single-wide, LP GPUs
  • Up to two double-wide, FHFL GPUs

For a list of supported GPUs, see Lenovo ServerProven website.

Integrated functions and I/O connectors
  • Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities.
  • Front connectors:
    • One USB 3.1 Gen 1 (5 Gbps) connector
    • One USB 2.0 connector with XCC system management function
    • One VGA connector
    • One external diagnostics handset connector (optional)
    • Front I/O module
      • System ID button/LED
      • System error LED
      • Network Activity LED
      • Power button/LED
  • Rear connectors:
    • Two OCP slots
    • One XCC system management port
    • Three USB 3.1 Gen 1 (5 Gbps) connectors
    • One serial port (optional)
    • One VGA connector
Network
Two or four Ethernet connectors on each OCP module (optional)
Rear button
NMI button
RAID adapter
Onboard NVMe ports with software RAID support (Intel VROC NVMe RAID)
  • Intel VROC Standard: requires an activation key and supports RAID levels 0, 1, and 10

  • Intel VROC Premium: requires an activation key and supports RAID levels 0, 1, 5, and 10

Hardware RAID 0, 1, 10
  • ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter
Hardware RAID 0, 1, 10, 5
  • ThinkSystem RAID 5350-8i PCIe 12Gb Adapter
Hardware RAID 0, 1, 10, 5, 50, 6, 60
  • ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter
Hardware RAID 0, 1, 10, 5, 50, 6, 60, 1 Triple, 10 Triple
  • ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter

For more information about the RAID/HBA adapters, see Lenovo ThinkSystem RAID Adapter and HBA Reference.

Host bus adapter
  • ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb Internal HBA
  • ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA
  • ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb External HBA
  • ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb External HBA
  • ThinkSystem 4350-8i SAS/SATA PCIe Gen3 12Gb Internal HBA
  • ThinkSystem 4350-16i SAS/SATA PCIe Gen3 12Gb Internal HBA

For more information about the RAID/HBA adapters, see Lenovo ThinkSystem RAID Adapter and HBA Reference.

System fan
The server supports one of the following fan types:
  • Six 60 mm x 38 mm single-rotor fans
  • Six 60 mm x 56 mm dual-rotor fans
Note
Do not mix single-rotor and dual-rotor fans in the same unit of server.
Electrical input
The server supports up to two power supplies with N+N redundancy with oversubscription. Following is the list of supported types:
  • CFFv4
    • 1100-watt Platinum, input power 115 Vac / 230 Vdc / 240 Vdc
    • 1100-watt Titanium, input power 115 Vac / 230 Vdc/ 240 Vdc
    • 1800-watt Platinum, input power 230 Vac / 240 Vdc
    • 1800-watt Titanium, input power 230 Vac / 240 Vdc
    • 2400-watt Platinum, input power 230 Vac / 240 Vdc
    • 2600-watt Titanium, input power 230 Vac / 240 Vdc
  • CRPS (Chinese Mainland Only)
    • 1300-watt Platinum, input power 115 Vac / 230 Vac / 240 Vdc
    • 2700-watt Platinum, input power 230 Vac / 240 Vdc
    • 1600-watt, input power 336 Vdc
    • 1600-watt, input power -48 Vdc
Important
Power supplies and redundant power supplies in the server must be with the same power rating, wattage or level.
CAUTION
  • 240 Vdc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY.
  • Power supply with 240 Vdc input cannot support hot-plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.
Note
The actual power efficiency depends on system configuration.
Minimal configuration for debugging
  • Two processors in socket 1 and 2
  • Two DRAM memory modules in slots 10 and 26
  • Two power supply units
  • Six system fans
  • One 2.5-inch drive, one M.2 drive, or one 7mm drive (if OS is needed for debugging)
Operating systems
Supported and certified operating systems:
  • Microsoft Windows Server
  • VMware ESXi
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
References: