Two-NVMe-backplane combinations
Follow the instructions in this section to learn how do cable routing for combinations with two NVMe backplanes.
Note
- See Connecting cables to the processor and memory expansion tray to perform the procedure properly while connecting PCIe cables to the processor and memory expansion tray.
- See Connecting cables to the NVMe switch cards to perform the procedure properly while connecting PCIe cables to the PCIe switch cards.
See the following sections for cable routing combinations with three AnyBay drive backplanes.
Two backplanes
Two NVMe backplanes
System board + processor and memory expansion tray
PCIe cable routing | ||
NVMe connector | Length | To |
1 0-1, 2-3 | 670 mm | PCIe 1 (on-board) |
2 4-5, 6-7 | 910 mm | PCIe 2 (on-board) |
3 0-1, 2-3 | 530 mm | PCIe 3 (tray) |
4 4-5, 6-7 | 670 mm | PCIe 6 (tray) |
Three backplanes
Two NVMe backplanes and one SAS/SATA backplane
System board + processor and memory expansion tray + 8i RAID adapter
SAS/SATA cable routing | PCIe cable routing | ||||
Length | To | NVMe connector | Length | To | |
1 | 1000 mm | C0 (8i) | 1 0-1, 2-3 | 670 mm | PCIe 1 (on-board) |
2 4-5, 6-7 | 910 mm | PCIe 2 (on-board) | |||
3 0-1, 2-3 | 530 mm | PCIe 3 (tray) | |||
4 4-5, 6-7 | 670 mm | PCIe 6 (tray) |