Skip to main content

Three-NVMe-backplane combinations

Follow the instructions in this section to learn how do cable routing for combinations with three NVMe backplanes.

Note

See the following sections for cable routing combinations with three AnyBay drive backplanes.

Three backplanes

Three NVMe backplanes

System board + processor and memory expansion tray + PCIe switch cards



PCIe cable routing
NVMe connectorLengthTo
1 0-1, 2-3670 mmPCIe 1 (on-board)
2 4-5, 6-7910 mmPCIe 2 (on-board)
3 0-1, 2-3530 mmPCIe 3 (tray)
4 4-5, 6-7670 mmPCIe 6 (tray)
5 0-1, 2-31100 mmC0, C1 (Slot 10)
6 4-5, 6-71100 mmC0, C1 (Slot 12)

Four backplanes

Three NVMe backplanes and one SAS/SATA backplane

System board + processor and memory expansion tray + PCIe switch cards + 8i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1820 mmC0 (8i)1 0-1, 2-3670 mmPCIe 1 (on-board)
   2 4-5, 6-7910 mmPCIe 2 (on-board)
  3 0-1, 2-3530 mmPCIe 3 (tray)
   4 4-5, 6-7670 mmPCIe 6 (tray)
   5 0-1, 2-31100 mmC0, C1 (Slot 10)
   6 4-5, 6-71100 mmC0, C1 (Slot 12)

Five backplanes

Three NVMe backplanes and two SAS/SATA backplanes

System board + processor and memory expansion tray + PCIe switch cards + 16i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1820 mmC0 (16i)1 0-1, 2-3670 mmPCIe 1 (on-board)
2860 mmC1 (16i)2 4-5, 6-7910 mmPCIe 2 (on-board)
  3 0-1, 2-3530 mmPCIe 3 (tray)
   4 4-5, 6-7670 mmPCIe 6 (tray)
   5 0-1, 2-31100 mmC0, C1 (Slot 10)
   6 4-5, 6-71100 mmC0, C1 (Slot 12)

Six backplanes

Three NVMe backplanes and three SAS/SATA backplanes

System board + processor and memory expansion tray + PCIe switch cards + 32i RAID adapter





SAS/SATA cable routingPCIe cable routing
 LengthToNVMe connectorLengthTo
1820 mmC0 (32i)1 0-1, 2-3670 mmPCIe 1 (on-board)
2690 mmC1 (32i)2 4-5, 6-7910 mmPCIe 2 (on-board)
3665 mmC2 (32i)3 0-1, 2-3530 mmPCIe 3 (tray)
   4 4-5, 6-7670 mmPCIe 6 (tray)
   5 0-1, 2-31100 mmC0, C1 (Slot 10)
   6 4-5, 6-71100 mmC0, C1 (Slot 12)