FQXSFMA0027M : DIMM [arg1] Self-healing, attempt post-package repair (PPR) failed at Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7]
DIMM [arg1] Self-healing, attempt post-package repair (PPR) failed at Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7]
Parameters
[arg1] DIMM Silk Label, 1-based
[arg2] Rank number
[arg3] Subrank number
[arg4] Bank number
[arg5] Row number
[arg6] DramDevice
[arg7] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
Severity
Warning
User Action
Complete the following steps:
- Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting detected change in DIMM population that could be related to this problem.)
- Boot to F1 setup and enable the DIMM. Reboot the system.
- Update UEFI firmware to the latest version.
- If the problem persists, collect Service Data logs and contact Lenovo Support.NoteThe solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.
Give documentation feedback