Install the power supply unit

Follow instructions in this section to install the power supply unit.

About this task

S001
shock hazard
DANGER
danger
Electrical current from power, telephone, and communication cables is hazardous.

To avoid a shock hazard:

  • Connect all power cords to a properly wired and grounded electrical outlet/source.
  • Connect any equipment that will be attached to this product to properly wired outlets/sources.
  • When possible, use one hand only to connect or disconnect signal cables.
  • Never turn on any equipment when there is evidence of fire, water, or structural damage.
  • The device might have more than one power cord, to remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
S002
disconnect all power
CAUTION
The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
S035
shock hazard
CAUTION

Never remove the cover on a power supply or any part that has this label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.
  • Touch the static-protective package that contains the component to any unpainted metal surface on the server; then, remove it from the package and place it on a static-protective surface.
  • Make sure the type of power supply is applicable to server drive configuration. See Mechanical specifications for more information.

Procedure

  1. Lower the power supply unit into the chassis, and slide it toward the opening on the rear side of chassis until the release tab snaps into place.
    Figure 1. Installing the power supply unit to the chassis
    Installing the power supply unit to the chassis
  2. From outside of the chassis, fasten the four screws to secure the power supply unit to the chassis.
    Figure 2. Securing the power supply unit to the chassis
    Securing the power supply unit to the chassis
  3. Connect the processor power cable and system power cable to the system board. See Internal cable routing.

After you finish

  1. Install the drive cage and the drive. See Simple-swap drive and drive cage replacement (bay 0-1).

  2. Install the server cover. See Install the server cover.

  3. Complete the parts replacement. See Complete the parts replacement.