Specifications
The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
Dimensions for tower form factor
Note The depth is measured with power supplies installed, but without the front door installed. |
Dimensions for rack form factor
Note The depth is measured with rack latches and power supplies installed. |
Weight
Up to 36.9 kg (79.4 lb), depending on the server configuration
Processor
Up to two Intel® Xeon® scalable processors
Scalable up to 22 cores
Designed for Land Grid Array (LGA) 3647 socket
Up to two Jintide® processors for Chinese Mainland only
Memory
For 1st Generation Intel Xeon Scalable Processors (Intel Xeon SP Gen 1) or Jintide processors
Minimum: 8 GB
Maximum:
384 GB using registered DIMMs (RDIMMs)
768 GB using load-reduced DIMMs (LRDIMMs)
Type:
TruDDR4 2666, single-rank/dual-rank, 8 GB/16 GB/32 GB registered DIMMs (RDIMMs)
TruDDR4 2666, quad-rank, 64 GB load-reduced DIMMs (LRDIMMs)
Slots: 12 DIMM slots
For 2nd Generation Intel Xeon Scalable Processors (Intel Xeon SP Gen 2)
Minimum: 8 GB
Maximum: 768 GB
Type:
TruDDR4 2666, single-rank/dual-rank, 16 GB/32 GB registered DIMMs (RDIMMs)
TruDDR4 2933, single-rank/dual-rank, 8 GB/16 GB/32 GB/64 GB registered DIMMs (RDIMMs)
Slots: 12 DIMM slots
Supported operating systems
Below lists all supported and certified operating systems:
Microsoft Windows Server
VMware ESXi
Red Hat Enterprise Linux
SUSE Linux Enterprise Server
For a complete list of operating systems, see:
For OS deployment instructions, see: Deploy the operating system.
Supported drives
The drives supported by your server vary by model.
Storage drive
Drive bay Supported drive type Eight 2.5-inch drive bays Hot-swap SAS/SATA/NVMe HDD or SSD (NVMe drives are supported only in bays 4–7 if an AnyBay backplane is installed) Sixteen 2.5-inch drive bays Hot-swap SAS/SATA/NVMe HDD or SSD (NVMe drives are supported only in bays 4–7 if an AnyBay backplane is installed) Twenty 2.5-inch drive bays Hot-swap SAS/SATA/NVMe HDD or SSD (NVMe drives are supported only in bays 4–7 if an AnyBay backplane is installed) Four 3.5-inch drive bays Simple-swap SATA HDD
Hot-swap SAS/SATA HDD or SSD
Eight 3.5-inch drive bays Simple-swap SATA HDD
Hot-swap SAS/SATA HDD or SSD
Eight 3.5-inch drive bays and four 2.5-inch drive bays Hot-swap SAS/SATA HDD or SSD To locate the storage drives or drive bays, see Front view.
Optical drive
Some server models have two optical drive bays. For more information, see Front view.
Tape drive
A tape drive enables you to store data on tape media. For server models with two optical drive bays, you can install an internal tape drive in the optical-drive bay 2.
M.2 drive
Your server supports one M.2 backplane which provides an easy way for data storage. You can install up to two M.2 drives into the M.2 backplane. For more information, see Install the M.2 backplane and M.2 drive.
Expansion slots
The server has six expansion slots on the system board for installing appropriate Peripheral Component Interconnect Express (PCIe) adapters.
For processor 1
PCIe slot 1: PCIe x8 (x8, x4, x1), full-height, half-length
PCIe slot 2: PCIe x16 (x16, x8, x4, x1), full-height, half-length
PCIe slot 3: PCIe x16 (x16, x8, x4, x1), full-height, full-length, double-width
PCIe slot 6: PCIe x8 (x4, x1), full-height, full-length
For processor 2
PCIe slot 4: PCIe x16 (x8, x4, x1), full-height, full-length
PCIe slot 5: PCIe x16 (x16, x8, x4, x1), full-height, full-length, double-width
SAS/SATA HBA adapters
ThinkSystem 430-8i SAS/SATA 12Gb HBA
ThinkSystem 430-16i SAS/SATA 12Gb HBA
ThinkSystem 430-8e SAS/SATA 12Gb HBA
ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA
ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA
ThinkSystem 4350-8i SAS/SATA 12Gb HBA
SAS/SATA RAID adapters
ThinkSystem RAID 530-8i PCIe 12Gb Adapter
ThinkSystem RAID 540-8i PCIe 12Gb Adapter
ThinkSystem RAID 730-8i 1GB Adapter
ThinkSystem RAID 730-8i 2GB PCIe Adapter
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
ThinkSystem RAID 940-8e 4GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter
ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter
ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter
ThinkSystem RAID 5350-8i PCIe 12Gb Adapter
ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter
RAID 730–8i 1G Cache SAS/SATA adapter is not available for North America.
RAID 530–8i SAS/SATA adapter cannot be mixed with RAID 730–8i 1G Cache SAS/SATA adapter.
RAID 730–8i 2G Flash SAS/SATA adapter cannot be mixed with RAID 730-8i 1G Cache SAS/SATA adapter or RAID 930–8i SAS/SATA adapter.
The RAID 940 adapters can be mixed with the ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA and the ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA.
Mixing of RAID/HBA 430/530/730/930 adapters (Gen 3) and RAID/HBA 440/540/940 adapters (Gen 4) in the same system is not allowed.
RAID 930/940 series or 9350 series adapters require a RAID flash power module.
RAID 4350/5350/9350 series adapters cannot be mixed with HBA/RAID 430/440/530/540/730/930/940 series SAS/SATA adapters.
For server models that support NVMe drives, the NVMe adapter (also known as the NVMe switch adapter) can be installed only in PCIe slot 2.
For RAID adapters or host bus adapters, you can install them in either PCIe slot 1 or PCIe slot 2.
For server models with one processor, you can install a double-width graphics adapter only in PCIe slot 3. For server models with two processors, you can install up to two double-width graphics adapters in PCIe slot 3 and PCIe slot 5. After any double-width graphics adapter is installed, PCIe slot 4 or PCIe slot 6 becomes unavailable because the space is occupied by the double-width adapter.
Graphics adapters
Your server supports the following GPUs:
Full-height, full-length, double-slot GPUs: NVIDIA P6000
Full-height, full-length, single-slot GPU: NVIDIA P4000, NVIDIA RTX4000.
Full-height, 3/4-length, single-slot GPU: NVIDIA P2000, NVIDIA P2200.
Low-profile, half-height, half-length, single-slot GPUs: NVIDIA P600, NVIDIA P620
Thermal Design Power (TDP): up to 250 watts
NVIDIA P4000 and NVIDIA RTX4000 are supported only in the new chassis. See Differences between the original chassis and new chassis
Your server supports up to two graphics adapters installed.
Graphics adapter is supported only when the following configuration requirements are met:
Fan 4 is installed.
Two 1100-watt power supplies are installed.
For NVIDIA P6000 graphics adapter, operating temperature is lower than 35°C (95°F) when one P6000 is installed, and operating temperature is lower than 30°C (86°F) when two are installed. For other supported graphics adapters, operating temperature is lower than 35°C (95°F) when one or two graphic adapters are installed.
- Fan redundancy function is supported when:
One NVIDIA P600, P620, P2000, P2200, P4000, or RTX4000 graphics adapter is installed
Two NVIDIA P600 or P620 graphics adapters are installed
Differences between the original chassis and new chassis
Two types of chassis are available for your server, and different chassis type supports different GPU models. You can identify the chassis type of your server by the rear view of your server or the part number label affixed on the bottom of your server.
Chassis type | Rear view | Part number | Supported GPU model |
---|---|---|---|
Original chassis |
|
| |
New chassis |
|
|
The new chassis is the updated version of the original chassis to support NVIDIA form factor V3.0 GPUs, such as NVIDIA P4000 and NVIDIA RTX4000.
The original chassis will phase out and be replaced by the new chassis.
Input/Output (I/O) features
Front panel:
One XClarity Controller USB connector
One USB 3.0 connector
Rear panel:
One VGA connector
One XClarity Controller network connector
Two Ethernet connectors
Two USB 3.0 connectors
Four USB 2.0 connectors
System fans
One processor: two fans (fan 1 and 2) or three fans (fan 1, 2, and 4)
Two processors: three fans (fan 1, 2, and 3) or four fans (fan 1, 2, 3, and 4)
Fan 3 is required if the expansion drive cage is installed.
Fan 4 is optional and is the redundant fan.
If your server comes with only one processor, two or three system fans are adequate to provide proper cooling. However, you must keep the location for fan 3 occupied by a fan filler to ensure proper airflow.
Power supplies
One fixed 450-watt power supply
One or two hot-swap power supplies for redundancy support
550-watt ac 80 PLUS Platinum
750-watt ac 80 PLUS Platinum
750-watt ac 80 PLUS Titanium
1100-watt ac 80 PLUS Platinum
Electrical input
ac input (50 Hz to 60 Hz) required
Input voltage low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input voltage high range:
Minimum: 200 V ac
Maximum: 240 V ac
Minimal configuration for debugging
One processor in processor socket 1
One memory DIMM on slot 3
One power supply
Two system fans (fan 1 and 2)
Acoustical noise
Sound power levels, idle
4.0 bels, minimum
4.7 bels, typical
5.3 bels, maximum
Sound power levels, operating
4.1 bels, minimum
4.7 bels, typical
5.3 bels, maximum
These sound power levels are measured in controlled acoustical environments according to procedures specified by ISO 7779 and are reported in accordance with ISO 9296.
The declared acoustic noise levels are based on specified configurations, which may change depending on configurations/conditions.
Environment
Air temperature:
Operating:
ASHRAE class A2: 10–35°C (50–95°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 300 m (984 ft) of altitude increase.
ASHRAE class A3: 5–40°C (41–104°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 175 m (574 ft) of altitude increase.
ASHRAE class A4: 5–45°C (41–113°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 125 m (410 ft) of altitude increase.
Server off: 5–45°C (41–113°F)
Shipping or storage: -40–60°C (-40–140°F)
Maximum altitude: 3050 m (10 000 ft)
Relative humidity (non-condensing):
- Operating:
ASHRAE class A2: 8%–80%; maximum dew point: 21°C (70°F)
ASHRAE class A3: 8%–85%; maximum dew point: 24°C (75°F)
ASHRAE class A4: 8%–90%; maximum dew point: 24°C (75°F)
Shipping or storage: 8%–90%
- Particulate contaminationAttentionAirborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server.
For information about the limits for particulates and gases, see Particulate contamination.
Fan 4 is installed.
Two hot-swap power supplies are installed.
NVMe SSD is not installed.
Graphics adapters are not installed.
SAS drives with capacity larger than or equal to 2 TB are not installed in the expansion drive cage.
Processors with TDP more than 125 watts are not installed.
Important information about EU ecodesign requirements
Minimum memory should be 16 GB.
Delta or Acbel 450-watt power supplies should not be picked.
Processors should not picked for one-processor configurations: Intel Xeon 3104, 3106, 3204, 4108, 4112, 5122, 5222, 8156, and 8256