Removing a ServeRAID M5215 controller
Use this information to remove a ServeRAID M5215 controller.
When the ServeRAID controller is removed, software RAID is not supported. The compute node does not support downgrading to the software RAID function from the hardware RAID configuration.
Before you remove the ServeRAID M5215 controller, complete the following steps:- Read Safety and Installation guidelines.
- If the compute node is installed in an Lenovo Flex System chassis, remove it (see Removing a compute node from a chassis for instructions).
- Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.
The ServeRAID M5215 controller uses a specific hard disk drive backplane.
- If you are removing the ServeRAID M5215 option from your compute node, you need to remove both the ServeRAID controller and its backplane, replacing the ServeRAID M5215 backplane with the hard disk drive backplane that came with your compute node.
- If you are removing only the ServeRAID M5215 controller to replace it, there is no need to remove the ServeRAID M5215 backplane.
To remove the ServeRAID M5215 controller, complete the following steps.
Note
For additional information about removing a ServeRAID M5215 controller, see "ServeRAID M5215 with 2GB Flash Enablement - Lenovo Flex System x240 M5 Installation Guide".
If you are instructed to return the ServeRAID controller or the ServeRAID controller backplane, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
Give documentation feedback