80070208-0a01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 1 Fan Fault)
Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 1 Fan Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
May also be shown as 800702080a01ffff or 0x800702080a01ffff
Severity
Error
Alert Category
Critical - Power
Serviceable
Yes
SNMP Trap ID
4
Automatically Notify Support
No
User Response
- Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan.
- Use the IBM Power Configurator utility to ensure current system power consumption is under limitation. For more information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
- Replace power supply n. (n = power supply number) PS 1 OP Fault : PS 1 Therm Fault :