The number of serial ports that are identified by the operating system is less than the number of installed serial ports. | - Make sure that the following conditions are met:
- Each port is assigned a unique address in both the Setup utility and the operating system, and none of the serial ports are disabled.
- The serial-port adapter (if one is present) is seated correctly.
- Reseat the serial port adapter.
- Replace the serial port adapter.
|
A serial device does not work. | - Make sure that the following conditions are met:
- Reseat the following components:
- Failing serial device
- Serial cable
- Replace the components listed in step 2 one at a time, in the order shown, restarting the server each time.
- Replace the serial adapter (if one is installed).
- (Trained service technician only) Replace the system board.
|