Lit light path diagnostics LED | Description | Action |
None | An error has occurred and cannot be isolated, or the service processor has failed. |
|
Battery error | The system battery is not installed or is not working. |
|
DIMM x error | A memory error occurred. | Look for system-event and IMM/AMM logs related to memory and resolve those events (see IMM error messages and UEFI/POST error codes). |
Front panel missing error | The front control panel is not installed correctly. | Make sure that the front control panel is installed correctly and the control panel cable is installed securely on the system board (see Installing the control panel). |
LP active | The system board light path LEDs have power. | Check for error LEDs that are lit on the system board. If this LED fails to light, install the blade server in a chassis for approximately 2 hours to enable the light path diagnostics panel to charge. |
Microprocessor error | The microprocessor has failed or overheated, or the start microprocessor is missing. |
|
Microprocessor mismatch | Microprocessor mismatch. | Make sure that microprocessors 1 and 2 are identical (number of cores, cache size and type, clock speed, internal and external clock frequencies).
|
NMI error | The system board has failed. |
|
SAS x error | A storage drive has failed. | Run the SAS Attached Disk diagnostic test. If the drives passes diagnostics but continues to have a problem, replace the storage drive with a new one. See IBM Dynamic System Analysis Preboot diagnostic program. |
System board error | The system board has failed. | (Trained technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly. |
Temperature error | The system temperature has exceeded a threshold level. |
|