0x80010200 | 80010202-0701ffff | Error | System board (SysBrd 3.3V) voltage (lower critical) has asserted. | - Remove all expansion cards from the blade server (see Removing an I/O expansion card).
- Remove all storage drives from the blade server (see Removing a hot-swap storage drive).
- If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80010200 | 80010202-0701ffff | Error | System board (SysBrd 5V) voltage (lower critical) has asserted. | - Remove all expansion cards from the blade server (see Removing an I/O expansion card).
- Remove all storage drives from the blade server (see Removing a hot-swap storage drive).
- If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80010200 | 80010202-0701ffff | Error | System board (SysBrd 12V) voltage (lower critical) has asserted. | - If the under voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events (see Event logs).
- View the event log provided by the advanced management module for your BladeCenter unit and resolve any power related errors that might be displayed.
- If other modules or blades are logging the same issue then check the power supply for the BladeCenter unit.
- If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80010200 | 80010202-0701ffff | Error | System board (CMOS battery) voltage (lower critical) has asserted. | Replace the system battery (see Removing the battery and Installing the battery). |
0x80010700 | 80010701-1001ffff 80010701-1002ffff 80010701-1003ffff 80010701-1004ffff | Warning | Expansion Module, (GPU_X TMP) temperature (upper non-critical) has asserted. [Note: X=1-4] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this temperature error.
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- View the event logs provided by the advanced management module for your BladeCenter unit and resolve any related errors that might be displayed.
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- Make sure that the heat sink is properly attached to the microprocessor (see Installing a microprocessor and heat sink).
|
0x80010700 | 80010701-2101ffff | Warning | System mgmt software (PCH Temp) temperature (upper non-critical) has asserted. | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Check the error logs about the temperature and the fan (see UEFI/POST error codes).
|
0x80010900 | 80010901-2101ffff | Error | System mgmt software (PCH Temp) temperature (upper non-critical) has asserted. | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Check the error logs about the temperature and the fan (see UEFI/POST error codes).
|
0x80010900 | 80010902-0701ffff | Error | System board (SysBrd 3.3V) voltage (upper critical) has asserted. | Replace the blade (see Removing the system-board assembly and Installing the system-board assembly). |
0x80010900 | 80010902-0701ffff | Error | System board (SysBrd 5V) voltage (upper critical) has asserted. | - Remove all expansion cards from the blade server (see Removing an I/O expansion card).
- Remove all storage drives from the blade server (see Removing a hot-swap storage drive).
- If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80010900 | 80010902-0701ffff | Error | System board (SysBrd 12V) voltage (upper critical) has asserted. | - If the over voltage problem is occurring on all blade servers, look for other events in the log related to power and resolve those events.
- View the event log provided by the advanced management module for your BladeCenter unit and resolve any power related errors that might be displayed.
- If other modules or blades are logging the same issue then check the power supply for the BladeCenter unit.
- If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80010b00 | 80010b01-1001ffff 80010b01-1002ffff 80010b01-1003ffff 80010b01-1004ffff | Error | Expansion Module, (GPU_X TMP) temperature (upper non-recoverable) has asserted. [Note: X=1-4] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this temperature error.
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- View the event logs provided by the advanced management module for your BladeCenter unit and resolve any related errors that might be displayed.
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- Make sure that the heat sink is properly attached to the microprocessor (see Installing a microprocessor and heat sink).
|
0x80010b00 | 80010b01-2101ffff | Error | System mgmt software (PCH Temp) temperature (upper non-recoverable) has asserted. | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Check the error logs about the temperature and the fan (see UEFI/POST error codes).
|
0x80030100 | 80030006-2101ffff | Info | Sensor (Sig Verify Fail) has deasserted. | Information only; no action is required. |
0x80030100 | 8003010e-2581ffff | Info | Sensor (Memory Resized) has asserted. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x80030100 | 8003010f-2101ffff | Info | System mgmt software, firmware progress (Phy Presence Jmp) has occurred. | Information only; no action is required. |
0x80030100 | 80030128-2101ffff | Info | System mgmt software, blade mgmt subsystem health (Low Security Jmp) has occurred. | Information only; no action is required. |
0x8006f0021 | 806f0021-2201ffff | Error | FW/BIOS, connector (No Op ROM Space) PCI express slot X fault. [Note: X=1,2] | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x80070100 | 80070101-0301ffff 80070101-0302ffff | Warning | Processor X, temperature (CPU X OverTemp) warning [Note: X=1,2] | - Check the system event log for additional temperature and fan information (see Event logs).
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- Make sure that the CPU heat sink is properly attached to the CPU (see Installing a microprocessor and heat sink).
|
0x80070100 | 80070101-0701ffff | Warning | System board, temperature (Inlet temp) warning | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
|
0x80070100 | 80070101-0701ffff | Warning | System board, temperature (VRD Hot) warning | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
|
0x80070100 | 80070101-1001ffff 80070101-1002ffff 80070101-1003ffff 80070101-1004ffff | Warning | Expansion Module, temperature (BPE4_X TMP) warning. [Note: X=1-4] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this temperature error.
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- View the event logs provided by the advanced management module for your BladeCenter unit and resolve any related errors that might be displayed.
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- Make sure that the heat sink is properly attached to the microprocessor (see Installing a microprocessor and heat sink).
|
0x80070100 | 80070114-2201ffff | Error | FW/BIOS, switch (TPM Lock) warning | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x80070200 | 80070201-0701ffff | Error | System board, temperature (Inlet temp) critical. | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure the air baffle and the fan fillers are installed correctly.
|
0x80070200 | 80070201-1001ffff 80070201-1002ffff 80070201-1003ffff 80070201-1004ffff | Error | Expansion Module, temperature (BPE4_X TMP) critical [Note: X=1-4] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this temperature error.
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- View the event logs provided by the advanced management module for your BladeCenter unit and resolve any related errors that might be displayed.
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- Make sure that the heat sink is properly attached to the microprocessor (see Installing a microprocessor and heat sink).
|
0x80070200 | 80070202-0701ffff | Error | System board, voltage (SysBrd Vol Fault) critical | - Reseat the blade server in the BladeCenter unit (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80070200 | 80070202-1001ffff 80070202-1002ffff 80070202-1003ffff 80070202-1004ffff | Error | Expansion Module 0 or 2, voltage (BPE4_X_VOL) critical [Note: X=1-4] | - If the under voltage problem is occurring on all blade servers, look for other events in the IMM2 event log related to power and resolve those events (see Event logs).
- View the event log provided by the advanced management module for your BladeCenter unit and resolve any power related errors that might be displayed.
- If other modules or blades are logging the same issue then check the system power supply, otherwise replace the Blade PCI Express I/O expansion unit. See Removing an optional expansion unit and Installing an optional expansion unit.
|
0x80070200 | 80070217-1001ffff 80070217-1002ffff 80070217-1003ffff 80070217-1004ffff | Error | Expansion Module 0 or 2, Expansion Card (BPE4_X Fault) critical [Note: X=1-4] | - View the event log provided by the advanced management module for your BladeCenter unit and resolve any expansion card related errors that might be displayed.
- If other modules or blades are logging the same issue then check the power supply for the BladeCenter unit.
- If the error still occurs, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80070200 | 80070219-0701ffff | Error | System board, chip set (SysBrd Fault) critical | - Make sure that the latest firmware is being used (see Updating firmware and device drivers).
- Reseat the blade server in the BladeCenter (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- Reset the UEFI firmware settings to default values using the Setup utility (see Using the Setup utility).
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- (Trained technician only) Replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80070200 | 8007021b-0301ffff 8007021b-0302ffff | Error | Processor X, interconnect (CPU X QPILinkErr) critical [Note: X=1,2] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this error.
- (Trained technician only) Reseat the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80070200 | 8007021b-0301ffff 8007021b-0302ffff | Error | Sensor (CPU X QPILinkErr) critical [Note: X=1,2] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this error.
- (Trained technician only) Reseat the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x80070200 | 8007020f-2201ffff | Error | FW/BIOS, firmware progress (TXT ACM Module) critical | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x80070200 | 8007020f-2582ffff | Error | Group 2, PCI express bus X, Expansion Module 2-0, firmware progress, no I/O resources. [Note: X=1, 2] | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x80070300 | 80070301-0301ffff 80070301-0302ffff | Error | Processor X, temperature (CPU X OverTemp) non-recoverable [Note: X=1, 2] | - Check the system event log for additional temperature and fan information (see Event logs).
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- Make sure that the CPU heat sink is properly attached to the CPU (see Installing a microprocessor and heat sink).
|
0x80070300 | 80070301-0701ffff | Error | System board, temperature (Inlet temp) non-recoverable. | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
|
0x80070300 | 80070301-1001ffff 80070301-1002ffff 80070301-1003ffff 80070301-1004ffff | Error | Expansion Module, temperature (BPE4_X_TMP) non-recoverable [Note: X=1-4] | - Check the IBM support website for an applicable retain tip or firmware update that applies to this temperature error.
- Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- View the event logs provided by the advanced management module for your BladeCenter unit and resolve any related errors that might be displayed.
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- Make sure that the heat sink is properly attached to the microprocessor (see Installing a microprocessor and heat sink).
|
0x80070300 | 80070302-1001ffff 80070302-1002ffff 80070302-1003ffff 80070302-1004ffff | Error | Expansion Module, voltage (BPE4_X_VOL) non-recoverable [Note: X=1-4] | - If the under voltage problem is occurring on all blade servers, look for other events in the IMM2 event log related to power and resolve those events (see Event logs).
- View the event log provided by the advanced management module for your BladeCenter unit and resolve any power related errors that might be displayed.
- If other modules or blades are logging the same issue then check the system power supply, otherwise replace the Blade PCI Express I/O expansion unit. See Removing an optional expansion unit and Installing an optional expansion unit.
|
0x80070600 | 8007060f-2201ffff | Error | FW/BIOS, firmware progress (BOFM cfg Err) non-recoverable | Install the latest UEFI firmware (see Updating firmware and device drivers). |
0x80070600 | 8007060f-2201ffff | Error | FW/BIOS, firmware progress (TPM Init Err) non-recoverable | Install the latest UEFI firmware (see Updating firmware and device drivers). |
0x800b0100 | 800b010c-2581ffff | Error | Redundancy Lost for (Backup Memory) has asserted. | - Check the event logs for other memory errors that might occur (see Event logs).
- Reseat all of the memory modules in the blade server (see Removing a memory module and Installing a memory module).
- Make sure all of the memory is enabled in the Setup utility (see Using the Setup utility). Notice which memory modules are disabled before continuing to the next step.
|
0x800b0300 | 800b030c-2581ffff | Warning | Non-redundant: Sufficient Resources from Redundancy Degraded or Fully Redundant for (Backup Memory) has asserted. | - Check the event logs for other memory errors that might occur (see Event logs).
- Reseat all of the memory modules in the blade server (see Removing a memory module and Installing a memory module).
- Make sure all of the memory is enabled in the Setup utility (see Using the Setup utility). Notice which memory modules are disabled before continuing to the next step.
|
0x800b0500 | 800b050c-2581ffff | Error | Non-redundant: Insufficient Resources for (Backup Memory) has asserted. | - Check the event logs for other memory errors that might occur (see Event logs).
- Reseat all of the memory modules in the blade server (see Removing a memory module and Installing a memory module).
- Make sure all of the memory is enabled in the Setup utility (see Using the Setup utility). Notice which memory modules are disabled before continuing to the next step.
|
0x806f0007 | 806f0007-0301ffff 806f0007-0302ffff | Error | Processor X (CPU X) has Failed with IERR. [Note X=1,2] | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
- (Trained technician only) If the problem continues, replace the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0009 | 806f0009-1301ffff | Info | Sensor (Host Power) has been turned off. | Information only; no action is required. |
0x806f000d | 806f000d-0400ffff 806f000d-0401ffff | Error | Hard drive X, (Drive X) removed [Note X=0,1] | Install the storage drive (see Installing a hot-swap storage drive). |
0x806f000f | 806f000f-220101xx | Error | FW/BIOS, firmware error. The System (ABR Status) has detected no memory in the system. | Install the latest UEFI firmware (see Recovering from a UEFI update failure). |
0x806f000f | 806f000f-220102xx | Error | FW/BIOS, firmware error. Subsystem (ABR Status) has insufficient memory for operation. | Install the latest UEFI firmware (see Recovering from a UEFI update failure). |
0x806f000f | 806f000f-220103xx | Error | FW/BIOS, firmware error. The System (ABR Status) encountered firmware error - unrecoverable boot device failure. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f000f | 806f000f-220104xx | Error | FW/BIOS, firmware error. The System (ABR Status) has encountered a motherboard failure. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f000f | 806f000f-220107xx | Error | FW/BIOS, firmware error. The System (ABR Status) encountered firmware error - unrecoverable keyboard failure. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f000f | 806f000f-22010axx | Error | FW/BIOS, firmware error. The System (ABR Status) encountered firmware error - no video device detected. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f000f | 806f000f-22010bxx | Error | Firmware BIOS (ROM) corruption was detected on system (ABR Status) during POST. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f000f | 806f000f-22010cxx | Error | CPU voltage mismatch detected on (ABR Status). | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f000f | 806f000f-2201ffff | Error | The System (ABR Status) encountered a POST Error. | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f0013 | 806f0013-1701ffff | Info | A diagnostic interrupt has occurred on system (NMI State). | - Verify that you have the latest system firmware (see Updating firmware and device drivers).
- If an expansion card is installed in the blade server, verify that the firmware for each expansion card is up to date.
- Run the Setup utility and restore system setting to defaults (see Using the Setup utility).
- Check the event logs for other related error messages (see Event logs).
- Remove each expansion card, one at a time until the error does not occur (see Removing an I/O expansion card).
- Replace failing adapter and reinstall any other expansion cards that were removed (see Installing an I/O expansion card).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0107 | 806f0021-1001ffff 806f0021-1002ffff 806f0021-1003ffff 806f0021-1004ffff | Error | Expansion Module, Fault in (Slot Y) on (BPE4_X, [Note: X=1-4, Y=1, 2] | - Check the event logs for other related error messages (see Event logs).
- Verify that you have the latest system firmware (see Updating firmware and device drivers).
- Run the Setup utility and restore system setting to defaults (see Using the Setup utility).
- Check the event logs for other related error messages (see Event logs).
- Reseat the expansion cards and PCIe adapters that are installed in the blade server (see Removing an I/O expansion card and Installing an I/O expansion card).
- Reseat the expansion unit.
- Remove each expansion card, one at a time until the error does not occur (see Removing an I/O expansion card).
- Replace failing adapter and reinstall any other expansion cards that were removed (see Installing an I/O expansion card).
- Replace the expansion unit (see Removing an optional expansion unit and Installing an optional expansion unit).
- If the system contains multiple microprocessors, swap the microprocessors (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0021 | 806f0021-2582ffff | Error | PCI error (All PCI Error) | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f0021 | 806f0021-2582ffff | Error | PCI error (One of PCI Error) | This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to UEFI/POST error codes for the appropriate actions. |
0x806f0021 | 806f0021-3101ffff | Error | PCI error (CIOv_STATUS) | - Check the operating system event log and the system event log as it may contain additional information (see Event logs).
- Reseat the blade server in the BladeCenter (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- Update the device drivers for any expansion cards that are installed into the blade server.
- Reseat the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
- Replace the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
|
0x806f0021 | 806f0021-3102ffff | Error | PCI error (CFFh_STATUS) | - Check the operating system event log and the system event log as it may contain additional information (see Event logs).
- Reseat the blade server in the BladeCenter (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- Update the device drivers for any expansion cards that are installed into the blade server.
- Reseat the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
- Replace the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
|
| 806f0023-2101ffff | Info | Watchdog Timer expired for sensor (IPMI Watchdog). | Information only; no action is required. |
0x806f0028 | 806f0028-2101ffff | Warning | Sensor (TPM Cmd Failures) is unavailable or degraded on management system. | - Restart the server.
- If the problem remains, or the server cannot be restarted successfully, (trained technician only) replace the system board (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0107 | 806f0107-0301ffff 806f0107-0302ffff | Error | Processor X (CPU X) Over-Temperature Condition has been detected. [Note: X=1,2] | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure that each bay of the BladeCenter unit has either a device or a filler installed.
- Make sure that the blade server is not missing any heat sinks, DIMMs, heat-sink fillers, or DIMM fillers (see Parts listing).
- Make sure that the CPU heat sink is properly attached to the CPU (see Installing a microprocessor and heat sink).
- (Trained technician only) If the error still occurs, replace the microprocessor that controls the failing memory module. See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink.
|
0x806f0108 | 806f0108-0701ffff | Error | System board, Power Module (VRD Fault) failure (VRD Fault) power supply failure detected. | - Make sure that the latest firmware is being used (see Updating firmware and device drivers).
- Reseat the blade server in the BladeCenter (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- Reset the UEFI firmware settings to default values using the Setup utility (see Using the Setup utility).
- (Trained technician only) Replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0109 | 806f0109-1301ffff | Info | (Host Power) has been Power Cycled. | Information only; no action is required. |
0x806f010c | 806f010c-2001ffff 806f010c-2002ffff 806f010c-2003ffff 806f010c-2004ffff 806f010c-2005ffff 806f010c-2006ffff 806f010c-2007ffff 806f010c-2008ffff 806f010c-2009ffff 806f010c-200affff 806f010c-200bffff 806f010c-200cffff | Error | Memory device X (DIMM X) uncorrectable ECC memory error [Note: X=1-12] | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Install the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error still occurs on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f010c | 806f010c-2581ffff | Error | Sensor (All DIMMs) uncorrectable ECC memory error. | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Install the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error still occurs on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f010c | 806f010c-2581ffff | Error | Sensor (One of the DIMMs) uncorrectable ECC memory error. | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Install the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error still occurs on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f010d | 806f010d-0400ffff 806f010d-0401ffff | Error | Hard drive X (Drive X) has been disabled due to a detected fault. [Note: X=0,1] | Replace the storage drive (see Removing a hot-swap storage drive and Installing a hot-swap storage drive). |
0x806f010f | 806f010f-2201ffff | Error | The system encountered a firmware (Firmware Error) hang | Install the latest UEFI firmware (see Recovering from a UEFI update failure). |
0x806f011b | 806f011b-0c01ffff | Error | The connector (Front Panel) has encountered a configuration error. | - Reseat the control-panel cable (see Removing the control panel and Installing the control panel).
- Replace the front bezel (see Removing the bezel assembly and Installing the bezel assembly).
- (Trained technician only) Replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
| 806f0123-2101ffff | Info | Reboot of system initiated by IPMI Watchdog. | Information only; no action is required. |
0x806f0207 | 806f0207-0301ffff 806f0207-0302ffff | Error | Processor X, (CPU X) has failed with FRB1/BIST condition. [Note: X=1,2] | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
- (Trained technician only) If the problem continues, replace the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0207 | 806f0207-2584ffff | Error | Processor X (All CPUs) has failed with FRB1/BIST condition. [Note: X=1,2] | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- If the problem continues, replace the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0207 | 806f0207-2584ffff | Error | Processor X (One of CPUs) has failed with FRB1/BIST condition. [Note: X=1,2] | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
- If the problem continues, replace the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f020d | 806f020d-0400ffff 806f020d-0401ffff | Warning | Hard drive X (Drive X) predictive failure [Note X=0,1] | Replace the storage drive (see Removing a hot-swap storage drive and Installing a hot-swap storage drive). |
| 806f0223-2101ffff | Info | Powering off system initiated by IPMI Watchdog. | Information only; no action is required. |
0x806f030c | 806f030c-2001ffff 806f030c-2002ffff 806f030c-2003ffff 806f030c-2004ffff 806f030c-2005ffff 806f030c-2006ffff 806f030c-2007ffff 806f030c-2008ffff 806f030c-2009ffff 806f030c-200affff 806f030c-200bffff 806f030c-200cffff | Error | Memory device X (DIMM X) memory scrub failed [Note: X=1-12] | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Install the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error still occurs on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f030c | 806f030c-2581ffff | Error | Memory device (All DIMMS) memory scrub failed. | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Install the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error still occurs on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f030c | 806f030c-2581ffff | Error | Memory device (One of the DIMMS) memory scrub failed. | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Install the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error still occurs on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f0313 | 806f0313-1701ffff | Error | A software NMI has occurred on system (NMI State). | - Verify that you have the latest system firmware (see Updating firmware and device drivers).
- If an expansion card is installed in the blade server, verify that the firmware for each expansion card is up to date.
- Run the Setup utility and restore system setting to defaults (see Using the Setup utility).
- Check the event logs for other related error messages (see Event logs).
- Reseat any expansion cards that are installed in the blade server (see Removing an I/O expansion card and Installing an I/O expansion card).
- Remove each expansion card, one at a time until the error does not occur (see Removing an I/O expansion card).
- Replace failing adapter and reinstall any other expansion cards that were removed (see Installing an I/O expansion card).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
| 806f0323-2101ffff | Info | Power cycle of system initiated by watchdog IPMI Watchdog. | Information only; no action is required. |
0x806f040c | 806f040c-2001ffff 806f040c-2002ffff 806f040c-2003ffff 806f040c-2004ffff 806f040c-2005ffff 806f040c-2006ffff 806f040c-2007ffff 806f040c-2008ffff 806f040c-2009ffff 806f040c-200affff 806f040c-200bffff 806f040c-200cffff | Info | Memory device X (DIMM X) memory disabled [Note X = 1-12] | - If the memory module was disabled because of a memory fault (error code 0x806f010c, 0x806f030c, or 0x806f050c), follow the procedure for that event and restart the server.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, re-enable the memory modules using the Setup utility or the Advanced Settings Utility (ASU).
|
0x806f040c | 806f040c-2581ffff | Info | Memory (All DIMMs) disabled. | - If the memory module was disabled due to a memory fault (error code 0x806f010c, 0x806f030c, or 0x806f050c), follow the procedure for that event and restart the server.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, re-enable the memory modules using the Setup utility or the Advanced Settings Utility (ASU).
|
0x806f040c | 806f040c-2581ffff | Info | Memory (One of the DIMMs) disabled. | - If the memory module was disabled due to a memory fault (error code 0x806f010c, 0x806f030c, or 0x806f050c), follow the procedure for that event and restart the server.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, re-enable the memory modules using the Setup utility or the Advanced Settings Utility (ASU).
|
0x806f0507 | 806f0507-0301ffff 806f0507-0302ffff | Error | Processor (CPU X) has a Configuration Mismatch [Note: X=1,2] | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
|
0x806f0507 | 806f0507-2584ffff | Error | Processor (All CPUs) has a Configuration Mismatch. | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
|
0x806f0507 | 806f0507-2584ffff | Error | Processor (One of CPUs) has a Configuration Mismatch. | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
|
0x806f050c | 806f050c-2001ffff 806f050c-2002ffff 806f050c-2003ffff 806f050c-2004ffff 806f050c-2005ffff 806f050c-2006ffff 806f050c-2007ffff 806f050c-2008ffff 806f050c-2009ffff 806f050c-200affff 806f050c-200bffff 806f050c-200cffff | Error | Memory device X (DIMM X) correctable ECC memory error logging limit reached [Note X = 1-12] | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Swap the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error occurs again on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f050c | 806f050c-2581ffff | Error | Memory (All DIMMs) correctable ECC memory error logging limit reached. | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Swap the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error occurs again on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f050c | 806f050c-2581ffff | Error | Memory (One of DIMMs) correctable ECC memory error logging limit reached. | - Refer to TIP H21455 for minimum code level.
- Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
- Swap the affected memory modules (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor (see Installing a memory module for memory population sequence).
- If the error occurs again on the same memory module, replace the affected memory module.
- (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector is damaged, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
- (Trained technician only) Replace the affected microprocessor (See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
|
0x806f050d | 806f050d-0400ffff 806f050d-0401ffff | Error | Hard drive X (Drive X) in critical condition. [Note X=0,1] | - Replace the storage drive (see Removing a hot-swap storage drive and Installing a hot-swap storage drive).
- After the storage drive has been replaced, rebuild the RAID array (see Creating a RAID array of hard disk drives).
|
0x806f052b | 806f052b-2101ffff | Error | Invalid or Unsupported firmware or software was detected on system (IMM2 FW Failover). | Make sure you have the latest system firmware (see Updating firmware and device drivers). |
0x806f0607 | 806f0607-0301ffff 806f0607-0302ffff | Error | Processor X (CPU X) SM BIOS uncorrectable CPU complex error [Note: X=1,2] | - Verify that you have the latest system firmware (see Updating firmware and device drivers).
- (Trained technician only) If the error still occurs, replace microprocessor X (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0607 | 806f0607-2584ffff | Error | Processor (All CPUs) SM BIOS uncorrectable CPU complex error. | - Verify that you have the latest system firmware (see Updating firmware and device drivers).
- Clear the CMOS data by removing the system battery for 30 seconds (see Removing the battery and Installing the battery).
- (Trained technician only) If the error still occurs, replace the microprocessors one at a time (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f0607 | 806f0607-2584ffff | Error | Processor (One of CPUs) SM BIOS uncorrectable CPU complex error. | - Verify that you have the latest system firmware (see Updating firmware and device drivers).
- (Trained technician only) If the error still occurs, replace the microprocessors one at a time (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
0x806f060d | 806f060d-0400ffff 806f060d-0401ffff | Error | Hard drive X (Drive X) in failed array [Note X=0,1] | - Replace the storage drive (see Removing a hot-swap storage drive and Installing a hot-swap storage drive).
- After the storage drive has been replaced, rebuild the RAID array (see Creating a RAID array of hard disk drives).
|
0x806f070c | 806f070c-2001ffff 806f070c-2002ffff 806f070c-2003ffff 806f070c-2004ffff 806f070c-2005ffff 806f070c-2006ffff 806f070c-2007ffff 806f070c-2008ffff 806f070c-2009ffff 806f070c-200affff 806f070c-200bffff 806f070c-200cffff | Error | Memory device X (DIMM X) memory configuration error [Note X=1-12] | Make sure that the memory modules are installed in the correct order and configured correctly (see Installing a memory module). |
0x806f070c | 806f070c-2581ffff | Error | Memory (All DIMMs) configuration error. | Make sure that the memory modules are installed in the correct order and configured correctly (see Installing a memory module). |
0x806f070c | 806f070c-2581ffff | Error | Memory (One of the DIMMs) configuration error. | Make sure that the memory modules are installed in the correct order and configured correctly (see Installing a memory module). |
0x806f050d | 806f070d-0400ffff 806f070d-0401ffff | Info | Hard drive X (Drive X) rebuilt in progress for Array in system. [Note X=0,1] | Information only; no action is required. |
0x806f0807 | 806f0807-0301ffff 806f0807-0302ffff | Info | Processor X (CPU X) has been disabled. [Note X=1,2] | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Check the event logs for other related error messages (see Event logs).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
|
0x806f0807 | 806f0807-2584ffff | Info | Processor (All CPUs) has been disabled. | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Check the event logs for other related error messages (see Event logs).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
|
0x806f0807 | 806f0807-2584ffff | Info | Processor (One of CPUs) has been disabled. | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Check the event logs for other related error messages (see Event logs).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
|
0x806f0813 | 806f0813-2581ffff | Error | Memory (DIMMs) uncorrectable error has occurred. | - Check the operating system event log and the system event log as it may contain additional information (see Event logs).
- Reseat the blade server in the BladeCenter (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- Update the device drivers for any expansion cards that are installed into the blade server.
- Reseat the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
- Replace the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
|
0x806f0813 | 806f0813-2582ffff | Error | PCI (PCIs) uncorrectable error has occurred. | - Check the operating system event log and the system event log as it may contain additional information (see Event logs).
- Reseat the blade server in the BladeCenter (see Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit).
- Update the device drivers for any expansion cards that are installed into the blade server.
- Reseat the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
- Replace the expansion card (see Removing an I/O expansion card and Installing an I/O expansion card).
|
0x806f0813 | 806f0813-2584ffff | Error | Processor (CPUs) uncorrectable error has occurred. | - Remove the blade server and ensure the processors are installed correctly (see Installing a microprocessor and heat sink).
- Verify that the system is running the latest UEFI firmware (see Updating firmware and device drivers).
- Run the Setup utility (see Using the Setup utility).
- Make sure that both processors are displayed by the system.
- Load the default settings.
- Go to the System Settings menu and make sure the processor is enabled.
- (Trained technician only) If the problem continues, replace the processor (see Removing a microprocessor and heat sink and Installing a microprocessor and heat sink).
- (Trained technician only) If the error continues, replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly).
|
| 806f0823-2101ffff | Info | Watchdog Timer interrupt occurred for sensor (IPMI Watchdog). | Information only; no action is required. |
| 806f090c-2001ffff 806f090c-2002ffff 806f090c-2003ffff 806f090c-2004ffff 806f090c-2005ffff 806f090c-2006ffff 806f090c-2007ffff 806f090c-2008ffff 806f090c-2009ffff 806f090c-200affff 806f090c-200bffff 806f090c-200cffff | Info | Memory device X, (DIMM X) memory Throttled X [Note X=1-12] | - Check the event logs for fan or cooling related issues (see Event logs).
- Make sure that the airflow at the front and rear of the chassis is not obstructed and the fillers are in place and correctly installed.
- Make sure that the room temperature is within the operating specifications.
- Make sure the air baffle and the fan fillers are installed correctly.
- If the problem remains and there is no other DIMM with the same issue, replace the affected DIMM (see Removing a memory module and Installing a memory module).
|
| 806f0a07-0301ffff 806f0a07-0302ffff | Warning | Processor X (CPU X) is operating in a Degraded State. [Note X=1,2] | - Check the event logs for fan, cooling, or power related issues (see Event logs).
- Make sure that the airflow at the front and rear of the chassis is not obstructed and the fillers are in place and correctly installed.
- Make sure that the room temperature is within the operating specifications.
- If the problem remains and there is no other DIMM with the same issue, replace the affected DIMM (see Removing a memory module and Installing a memory module).
|
0x806f0a0c | 806f0a0c-2001ffff 806f0a0c-2002ffff 806f0a0c-2003ffff 806f0a0c-2004ffff 806f0a0c-2005ffff 806f0a0c-2006ffff 806f0a0c-2007ffff 806f0a0c-2008ffff 806f0a0c-2009ffff 806f0a0c-200affff 806f0a0c-200bffff 806f0a0c-200cffff | Error | Memory device X, (DIMM X) memory in critical over-temperature state Throttled X [Note X=1-12] | - Make sure that the room temperature is within the operating specifications (see Features and specifications).
- Make sure that none of the air vents on the BladeCenter unit and on the blade server are blocked.
- Make sure that all of the fans on the BladeCenter unit are running.
- Make sure the air baffle and the fan fillers are installed correctly.
|