FQXPMEM0007M : Diagnostic image cannot be launched as "Console Redirection" is enabled
Diagnostic image cannot be launched as "Console Redirection" is enabled
Severity
Critical
Serviceable with log
No
Automatically Notify Support
No
User Action
1) Disable “Configure Console Redirection” in UEFI Setup.\n2) Perform AC reset if the error still exist.\nNote:\n When performing AC reset, after power off AC, wait several seconds before power on AC. After AC power is restored, power on the host system.\n3) If the error still occurs, contact service to support.