Skip to main content

FQXSFIO0041J : PCIe Leaky Bucket Event : [arg1] occurred at Segment [arg2] Bus [arg3] Device [arg4] Function [arg5]. The physical [arg6] number is [arg7].

PCIe Leaky Bucket Event : [arg1] occurred at Segment [arg2] Bus [arg3] Device [arg4] Function [arg5]. The physical [arg6] number is [arg7].

Parameters

[arg1] PCIe Leaky Bucket Event

[arg2] Segment

[arg3] Bus

[arg4] Device

[arg5] Function

[arg6] Slot/Bay

[arg7] Instance number

Severity

Warning

User Action

Complete the following steps:

  1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve that error.

  2. Check the Lenovo Support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.

  3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible PCIe slot or bay and a compatible cable is used. If not, performance of this device might be impacted.

  4. If the problem persists, collect Service Data logs and contact Lenovo Support.