Skip to main content

FQXSFMA0054G : Mirror failover operation was successful. DIMM [arg1] has failed over to the mirrored DIMM [arg2].[arg3]

Mirror failover operation was successful. DIMM [arg1] has failed over to the mirrored DIMM [arg2].[arg3]

Parameters

[arg1] DIMM Silk Label, 1-based

[arg2] DIMM Silk Label, 1-based

[arg3] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"

Severity

Warning

User Action

Complete the following steps:

  1. Keep the system running until next planned maintenance window.

  2. During planned maintenance, power off the system and remove A/C power.

  3. Reseat the failing DIMM identified by LightPath and/or event log entry.

  4. Restore A/C power and power on the system.

  5. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.

  6. If the problem persists, collect Service Data logs and contact Lenovo Support.