Skip to main content

FQXSFMA0056M : An uncorrected recoverable memory error has been detected on DIMM [arg1] at address [arg2].[arg3]

An uncorrected recoverable memory error has been detected on DIMM [arg1] at address [arg2].[arg3]

Parameters

[arg1] DIMM Silk Label, 1-based

[arg2] Address of the system where error occurred

[arg3] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"

Severity

Error

User Action

  1. Power off the system and remove A/C power.

  2. Reseat the failing DIMM identified by LightPath and/or event log entry

  3. Restore A/C power and power on the system.

  4. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.

  5. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.

  6. If the problem persists, collect Service Data logs and contact Lenovo Support.