Skip to main content

FQXSFMA0036M : DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory interleave set is missing.

DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory interleave set is missing.

Parameters

[arg1] Missed DIMM Silk Label

[arg2] Missed DIMM UID

Severity

Warning

User Action

Complete the following steps:

  1. Collect XCC Service Data.
  2. Power off system.
  3. This error message will provide the UID of the missing DCPMM,
  4. Use Lenovo Service Client or contact Lenovo Support to parse log to get correct location for DCPMM Find the missing DCPMM and install it in the correct location.
  5. If an error occurs, follow steps 1 and 4 to get details on new error message.
  6. If the problem persists, collect Service Data logs and contact Lenovo Support.