To complete the parts replacement, do the following:
  1. Ensure that all components have been reassembled correctly and that no tools or loose screws are left inside your server.

  2. Properly route and secure the cables in the server. Refer to the cable connecting and routing information for each component.

  3. Reinstall the air baffles. See Install the air baffle.
    Attention
    For proper cooling and airflow, reinstall the air baffle before turning on the server. Operating the server with the air baffle removed might damage server components.
  4. Reinstall the middle top cover. See Install the middle top cover.

  5. Reinstall the rear top cover. See Install the rear top cover.

  6. If the sever was installed in a rack, reinstall the server into the rack. See Install a node to the rack.

  7. Reconnect the power cords and any cables that you removed.

  8. Install the I/O fillers to the front and rear side of the node when the connectors are not used. The connectors could be dust–covered without proper protection of the fillers. See Node I/O connector fillers.

  9. If the security LED of the server is blinking, the server is in System Lockdown Mode. Activate or unlock the system for operation. See Activate or unlock the system.

  10. Power on the server and any peripheral devices. See Power on the server.

  11. Update the server configuration.