System-board switches
The following illustrations show the location of the switches on the system board.
Note
If there is a clear protective sticker on the top of the switch blocks, you must remove and discard it to access the switches.
Figure 1. System-board switches
The following table describes the switches on the system board.
Switches block | Switch number | Switch name | Usage description | |
---|---|---|---|---|
On | Off | |||
SW5 | 1 | Machine Engine (ME) firmware security override | ME update mode | Normal (default) |
SW1 | 1 | XClarity Controller boot backup | The node will boot by using a backup of the XClarity Controller firmware | Normal (default) |
2 | XClarity Controller force update | Enables XClarity Controller force update | Normal (default) | |
3 | Password override | Overrides the power-on password | Normal (default) | |
4 | Low security | Enable low security | Normal (default) | |
SW10 | 4 | CMOS clear | Clears the real-time clock (RTC) registry | Normal (default) |
Important
- Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. Review the information in Safety Information page, Installation Guidelines, Handling static-sensitive devices, and Power off the server.
- Any system-board switch or jumper block that is not shown in the illustrations in this document are reserved.
Give documentation feedback