Skip to main content

FQXSPPW0079N : Sensor [SensorElementName] has transitioned to non-recoverable.

Sensor [SensorElementName] has transitioned to non-recoverable.

This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

Severity​

Error

Alert Category​

Critical - Voltage

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0530

SNMP Trap ID​

1

Automatically Notify Support​

No

User Action​

Complete the following steps:

  1. If the sensor is DIMM {N} PMIC.
    1. Power off the system and remove A/C power.
    2. Reseat the DIMM in the slot specified by the event message. Restore A/C power and power on the system.
    3. If the problem persist collect Service Data log.
    4. Contact Lenovo Support.
  2. If the sensor is not DIMM {N} PMIC.
    1. AC cycle the system.
    2. If the problem persist collect Service Data log.
    3. Contact Lenovo Support.