본문으로 건너뛰기

6 x 2.5'' SAS/SATA + 2 x 2.5'' NVMe + 2 x 2.5'' AnyBay backplane (two processors)

Use this section to understand the AnyBay backplane cable routing for server model with ten 2.5-inch front drives and two processors.

Figure 1. Cable routing for 6 x 2.5'' SAS/SATA, 2 x 2.5'' NVMe, and 2 x 2.5'' AnyBay drives, and 1 x 16i/8i SFF RAID adapter (Gen 3/Gen 4)
Cable routing for 6 x 2.5'' SAS/SATA, 2 x 2.5'' NVMe, and 2 x 2.5'' AnyBay drives, and 1 x 16i/8i SFF RAID adapter (Gen 3/Gen 4)

Table 1. Mapping between RAID adapter, backplane, and processor board
FromToCable length
1 SAS 0 and SAS 1 connectors on backplane1
  • C0 and C1 connectors on Gen 3 RAID adapter

  • C0 connector on Gen 4 RAID adapter

  • Gen 3: 820/1020 mm

  • Gen 4: 900/1020 mm

2 Power connector on backplane2 Power connector 2A connector on processor board480 mm
3 NVMe 6-7 connector on backplane3 PCIe connector 4 on processor board250 mm
4 NVMe 8-9 connector on backplane4 PCIe connector 3 on processor board350 mm
Figure 2. Cable routing for 6 x 2.5'' SAS/SATA, 2 x 2.5'' NVMe, and 2 x 2.5'' AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)
Cable routing for 6 x 2.5'' SAS/SATA, 2 x 2.5'' NVMe, and 2 x 2.5'' AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 4)

FromToCable length
1 SAS 0 connector on backplane1 C0 connector on RAID adapter175 mm
2 Input connector on RAID adapter2 PCIe connector 8 on processor board450 mm
3 Power connector on backplane3 Power connector 2A on processor board480 mm
4 SAS 1 connector on backplane4 C1 connector on RAID adapter150 mm
5 NVME 6-7 connector on backplane5 PCIe connector 4 on processor board250 mm
6 NVME 8-9 connector on backplane6 PCIe connector 3 on processor board350 mm
7 Power connector on RAID adapter7 Internal RAID power connector on processor board210 mm