FQXSPPW0035M : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.

Severity

Error

Alert Category

Critical - Voltage

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0480

SNMP Trap ID

1

Automatically Notify Support

Yes

User Action

Complete the following steps until the problem is solved:

  1. If the sensor is "CMOS Battery":
    1. Reboot the XCC.
    2. Reseat the CMOS battery.
    3. If the problem persists, replace the CMOS battery.
  2. If the sensor is "SysBrd 3.3V/5V/12V":
    1. Do virtual AC cycle through the XCC/BMC.
    2. If problem persists, collect service data log.
    3. AC cycle the system.
    4. If the problem still persists, collect service data log and contact Lenovo Support.