FQXSPUN0020N : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

Severity

Error

Alert Category

Critical - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0524

SNMP Trap ID

50

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. If the sensor is in "ME Status":
    1. Reboot XCC and see if the issue is still observed.
    2. Upgrade or downgrade the UEFI to have ME update and see if the issue disappears.
    3. If the problem persists, contact Lenovo Support and replace the system board.
  2. If the sensor is in "RAID Vol State":
    1. Check Lenovo Support (http://support.lenovo.com/) for service bulletins, Tech tips, and firmware update related to your drive.
    2. Check for any other RAID-related error.
    3. Replace the drive and recreate an array.