Skip to main content

7mm drives

This section provides cable routing information for the 7mm drives.

Note
The following uses the 7mm drives installed on riser 2 as an example for illustration. The cable routing for 7mm drives installed on riser 1 is similar.

7mm non-RAID SATA/NVMe 2-Bay backplanes

Note
The 7mm non-RAID SATA/NVMe 2-Bay backplanes support SATA cable connection, NVMe cable connection, or RAID cable connection.
Figure 1. Power cable routing

Figure 2. SATA cable routing

FromToFromTo
1 Power connector on the 7mm backplane1 7mm power connector on the system board assembly1 Signal connector on the 7mm drive backplane1 M.2/7mm backplane signal connector on the system board assembly
Figure 3. NVMe cable routing

Note
The illustration shows four NVMe cable connection options, but the four options are mutually exclusive. Select one of them based on your scenario.
Figure 4. RAID cable routing

FromToFromTo
Signal connector on the 7mm drive backplane1 PCIe 11 Signal connector on the 7mm drive backplane1 8i adapter: C0
2 PCIe 3 (one processor installed)  
3 PCIe 8  
4 PCIe 10  

7mm RAID NVMe 2-Bay backplanes

7mm RAID SATA/NVMe 2-Bay backplanes

Note
The cable routing for 7mm RAID NVMe 2-Bay backplanes is the same as that for 7mm RAID SATA/NVMe 2-Bay backplanes.
Figure 5. Power cable routing

Figure 6. Signal cable routing

FromToFromTo
1 Power connector on the 7mm backplane1 7mm power connector on the system board assembly1 Signal connector on the 7mm drive backplane1 M.2/7mm backplane signal connector on the system board assembly