Skip to main content

Technical specifications

Summary of the technical specifications of server. Depending on the model, some features might not be available, or some specifications might not apply for your server model.

Processor
Supports multi-core Intel Xeon processors, with integrated memory controller and Intel Mesh UPI (Ultra Path Interconnect) topology.
  • Up to two 4th or 5th Gen Intel Xeon scalable processors with the new LGA 4677 socket

  • Up to 60 cores per socket for 4th Gen processors and 64 cores per socket for 5th Gen processors

  • Up to 4 UPI links at up to 16 GT/s for 4th Gen processors and 20 GT/s for 5th Gen processors

  • Thermal Design Power (TDP): up to 350 watts for 4th Gen processors and 385 watts for 5th Gen processors

For a list of supported processors, see Lenovo ServerProven website.

Memory
  • Slots: 32 dual inline memory module (DIMM) connectors that support up to 32 TruDDR5 DIMMs

  • Memory module types for 4th Gen processors:

    • TruDDR5 4800 MHz RDIMM: 16 GB (1Rx8), 32 GB (2Rx8)

    • TruDDR5 4800 MHz 10x4 RDIMM: 32 GB (1Rx4), 64 GB (2Rx4)

    • TruDDR5 4800 MHz 9x4 RDIMM: 32 GB (1Rx4), 64 GB (2Rx4)

    • TruDDR5 4800 MHz 3DS RDIMM: 128 GB (4Rx4), 256 GB (8Rx4)

  • Memory module types for 5th Gen processors:

    • TruDDR5 5600 MHz RDIMM: 16 GB (1Rx8), 24 GB (1Rx8), 32 GB (2Rx8), 48 GB (2Rx8)

    • TruDDR5 5600 MHz 10x4 RDIMM: 32 GB (1Rx4), 48 GB (1Rx4), 64 GB (2Rx4), 96 GB (2Rx4)

    • TruDDR5 5600 MHz 3DS RDIMM: 128 GB (4Rx4)

  • Speed: Operating speed depends on processor model and UEFI settings.
    • 4800 MHz RDIMMs:
      • 1 DPC: 4800 MT/s

      • 2 DPC: 4400 MT/s

    • 5600 MHz RDIMMs:
      • 1 DPC: 5600 MT/s

      • 2 DPC:
        • 4800 MT/s for Performance + RDIMMs

        • 4400 MT/s

  • Minimum memory: 16 GB

  • Maximum memory: 8 TB: 32 x 256 GB 3DS RDIMMs

For a list of supported memory modules, see Lenovo ServerProven website.

Internal drives
  • Front drive bays:

    • Up to 24 x 2.5-inch hot-swap SAS/SATA/NVMe drives

    • Up to 12 x 3.5-inch hot-swap SAS/SATA drives

    • Up to 4 x 3.5-inch hot-swap NVMe drives

  • Middle drive bays:

    • Up to 8 x 2.5-inch hot-swap SAS/SATA/NVMe drives

    • Up to 4 x 3.5-inch hot-swap SAS/SATA drives

  • Rear drive bays:

    • Up to 8 x 2.5-inch hot-swap SAS/SATA drives

    • Up to 4 x 3.5-inch hot-swap SAS/SATA drives

    • Up to 4 x 2.5-inch hot-swap NVMe drives

    • Up to two 7mm drives

  • Up to two internal M.2 drives

Expansion slots
  • Up to ten PCIe slots in the rear and two PCIe slots in the front

  • One OCP module slot

PCIe slot availability is based on riser selection and rear drive bay selection. See Rear view and PCIe slots and PCIe adapters.

RAID adapter
  • Onboard SATA ports with software RAID support (Intel VROC SATA RAID, supporting RAID levels 0, 1, 5, and 10)

  • Onboard NVMe ports with software RAID support (Intel VROC NVMe RAID)

    • Intel VROC standard: requires an activation key and supports RAID levels 0, 1, and 10

    • Intel VROC Premium: requires an activation key and supports RAID levels 0, 1, 5, and 10

    • Intel VROC Boot (for 5th Gen processors): requires an activation key and supports RAID level 1 only

  • Hardware RAID levels 0, 1, 10:
    • ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter

  • Hardware RAID levels 0, 1, 5, 10:
    • ThinkSystem RAID 5350-8i PCIe 12Gb Adapter

    • ThinkSystem RAID 5350-8i PCIe 12Gb Internal Adapter*

  • Hardware RAID levels 0, 1, 5, 6, 10, 50, 60:
    • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter

    • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Internal Adapter*

    • ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter

    • ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Internal Adapter*

    • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter*

    • ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter

Note
  • *Custom form factor (CFF) adapters that are supported only for server models with 2.5-inch front drive bays.

  • 4510T, 4510, 4509Y, and 3508U processors do not support Intel VROC NVMe RAID.

  • For more information about the RAID/HBA adapters, see Lenovo ThinkSystem RAID Adapter and HBA Reference.

Host bus adapter (HBA)/Expander
  • ThinkSystem 4350-8i SAS/SATA 12Gb HBA

  • ThinkSystem 4350-16i SAS/SATA 12Gb HBA

  • ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA

  • ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA

  • ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb Internal HBA*

  • ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA

  • ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA

  • ThinkSystem 48 port 12Gb Internal Expander*

Note
Graphics processing unit (GPU)
Your server supports the following GPUs:
  • Double-wide: NVIDIA® A16, A30, A40, A100, A800, H100, H800, L40, L40S, RTX A2000, RTX A4500, RTX A6000, AMD® Instinct MI210

  • Single-wide: NVIDIA A2, T1000, T400, L4

Note
  • For GPU supporting rules, see Thermal rules.

  • To prevent potential thermal issues, change the Misc setting in the BIOS from Option3 (default value) to Option1 if the following two conditions are met:
    • The server is equipped with a GPU adapter.

    • The UEFI firmware version is ESE122T or later.

    For the method of changing the Misc setting, see https://support.lenovo.com/us/en/solutions/TT1832.
Integrated functions and I/O connectors
  • Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities.

  • Front connectors:

    • One VGA connector (optional)

    • One USB 3.2 Gen1 (5 Gbps) connector

    • One USB 2.0 connector with XCC system management function

    • One external diagnostics connector

    • One integrated diagnostics panel (optional)

  • Rear connectors:

    • One VGA connector

    • Three USB 3.2 Gen1 (5 Gbps) connectors

    • One XCC system management port

    • Two or four Ethernet connectors on the OCP module (optional)

    • One serial port (optional)

Network
  • OCP module in the front or rear of the server, which provides two or four Ethernet connectors for network support

    Note
    If the ThinkSystem V3 Management NIC Adapter Kit (management NIC adapter) is installed on the server, it will not be displayed on the PCIe card list of system management software, such as XCC, LXPM, and so on.
System fan
  • Supported fan types:
    • Standard fan (60 x 60 x 36 mm, single-rotor, 17000 RPM)

    • Performance fan (60 x 60 x 56 mm, dual-rotor, 21000 RPM)

  • Fan redundancy: N+1 redundancy, one redundant fan rotor

    • One processor: five hot-swap system fans (one redundant fan rotor)

    • One processor with middle/rear bay or Riser 3, or two processors: six hot-swap system fans (one redundant fan rotor)

Note
  • Single-rotor hot-swap fans cannot be mixed with dual-rotor hot-swap fans.

  • The redundant cooling by the fans in the server enables continued operation if one rotor of a fan fails.

  • When the system is powered off but still plugged in to AC power, fans 1 and 2 may continue to spin at a much lower speed. This is the system design to provide proper cooling.

Power supplies
The server supports up to two hot-swap power supplies for redundancy.
Power supply100–127 V ac200–240 V ac240 V dc-48 V dc
750W Platinum 
750W Titanium  
1100W Platinum 
1100W Titanium  
1800W Platinum  
1800W Titanium  
2400W Platinum  
2600W Titanium  
1100W -48V DC   
CAUTION
  • 240 V dc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY.

  • Power supply with 240 V dc input cannot support hot plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.

Operating systems
Supported and certified operating systems:
  • Microsoft Windows Server

  • Microsoft Windows

  • Red Hat Enterprise Linux

  • SUSE Linux Enterprise Server

  • VMware ESXi

  • Canonical Ubuntu

References:
Minimal configuration for debugging
  • One processor in socket 1
  • One DIMM in slot 7
  • One power supply
  • One HDD/SSD drive, one M.2 drive, or one 7mm drive (if OS is needed for debugging)
  • Five system fans