FQXSPMA0034M : System had DIMM PMIC power fault, DIMM need to replace, NO virtual reseat function.

System had DIMM PMIC power fault, DIMM need to replace, NO virtual reseat function.

This message is for the use case when an implementation has detected System had DIMM PMIC power fault.

Severity

Error

Alert Category

Critical - Memory

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0522

SNMP Trap ID

41

Automatically Notify Support

No

User Action

Complete the following steps:

  1. Power off the system and remove A/C power.
  2. Reseat the DIMM in the slot specified by the event message FQXSPPW0079N.
  3. Restore A/C power and power on the system.
  4. If problem persists, collect Service Data log.