Front view
This section contains information about the controls, LEDs, and connectors on the front of the server.
Eight 3.5-inch simple-swap drives bays
1 Front I/O module | 2 3.5-inch simple-swap drive bays
|
3 3.5-inch simple swap SATA drive bays (Bay 0-3) |
For more information about the front I/O module, see Front I/O module.
The drive bays are used to install 3.5-inch simple-swap drives. When you install drives, follow the order of the drive bay numbers. The EMI integrity and cooling of the server are protected by having all drive bays occupied. The vacant drive bays must be occupied by drive bay fillers or drive fillers.
For more information about drive LEDs, see Drive LEDs.
Six 3.5-inch simple-swap drives bays
1 Front I/O module | 2 Optical-drive bay 2 |
3 Optical-drive bay 1 | 4 3.5-inch simple-swap SATA drive bays (Bay 4-5) |
5 3.5-inch simple swap SATA drive bays (Bay 0-3) |
For more information about the front I/O module, see Front I/O module.
Depending on the model, the server might come with an optical drive or a tape drive installed in the lower 5.25-inch optical-drive bay. The upper 5.25-inch optical-drive bay is for a secondary optical drive. Some models have a secondary optical drive installed.
The drive bays are used to install 3.5-inch simple-swap drives. When you install drives, follow the order of the drive bay numbers. The EMI integrity and cooling of the server are protected by having all drive bays occupied. The vacant drive bays must be occupied by drive bay fillers or drive fillers.
For more information about drive LEDs, see Drive LEDs.
Eight 3.5-inch hot-swap drives bays
1 Front I/O module | 2 Optical-drive bay 2 |
3 Optical-drive bay 1 | 4 3.5-inch hot-swap SAS/SATA drive bays (Bay 4-7) |
5 3.5-inch hot-swap SAS/SATA drive bays (Bay 0-3) |
For more information about the front I/O module, see Front I/O module.
Depending on the model, the server might come with an optical drive or a tape drive installed in the lower 5.25-inch optical-drive bay. The upper 5.25-inch optical-drive bay is for a secondary optical drive. Some models have a secondary optical drive installed.
The drive bays are used to install 3.5-inch hot-swap drives. When you install drives, follow the order of the drive bay numbers. The EMI integrity and cooling of the server are protected by having all drive bays occupied. The vacant drive bays must be occupied by drive bay fillers or drive fillers.
For more information about drive LEDs, see Drive LEDs.
Sixteen 2.5-inch hot-swap drives bays
1 Front I/O module | 2 Optical-drive bay 2 |
3 Optical-drive bay 1 | 4 2.5-inch hot-swap SAS/SATA drive bays (Bay 8-15) |
5 2.5-inch hot-swap SAS/SATA drive bays (Bay 0-7) |
For more information about the front I/O module, see Front I/O module.
Depending on the model, the server might come with an optical drive or a tape drive installed in the lower 5.25-inch optical-drive bay. The upper 5.25-inch optical-drive bay is for a secondary optical drive. Some models have a secondary optical drive installed.
The drive bays are used to install eight 2.5-inch hot-swap drives. When you install drives, follow the order of the drive bay numbers. The EMI integrity and cooling of the server are protected by having all drive bays occupied. The vacant drive bays must be occupied by drive bay fillers or drive fillers.
For more information about drive LEDs, see Drive LEDs.
Four 3.5-inch hot-swap + eight 2.5-inch hot-swap drives bays
1 Front I/O module | 2 Optical-drive bay 2 |
3 Optical-drive bay 1 | 4 3.5-inch hot-swap SAS/SATA drive bays (Bay 4-11) |
5 2.5-inch hot-swap SAS/SATA drive bays (Bay 0-3) |
For more information about the front I/O module, see Front I/O module.
Depending on the model, the server might come with an optical drive or a tape drive installed in the lower 5.25-inch optical-drive bay. The upper 5.25-inch optical-drive bay is for a secondary optical drive. Some models have a secondary optical drive installed.
The drive bays are used to install 2.5-inch and 3.5-inch hot-swap drives. When you install drives, follow the order of the drive bay numbers. The EMI integrity and cooling of the server are protected by having all drive bays occupied. The vacant drive bays must be occupied by drive bay fillers or drive fillers.
For more information about drive LEDs, see Drive LEDs.