1 x SAS/SATA + 2 x AnyBay backplanes
This section lists the required components for server models with 1 x SAS/SATA + 2 x AnyBay 3.5-inch hot-swap backplanes.
Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
When routing the cables, ensure that all cables are routed appropriately through the cable guides and cable clips.
Y-cables are shown as individual cables in the illustrations for each backplane.
Secure unused end of Y-cable under the cable clip.
Connect cables prioritizing Gen 4 RAID adapters.
For more information on the cables that are used, see Backplane cable list.
Onboard NVMe/SATA + 1 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 1. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to MCIO x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 2. SAS/SATA cable routing to system board and PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3 (onboard) | SlimSAS x4 to SlimSAS x4 (540 mm) |
2 BP2: SAS/SATA | SATA 4-7 (onboard) | SlimSAS x4 to SlimSAS x4 (540 mm) |
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 2 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 3. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to MCIO x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 4. SAS/SATA cable routing to top PCIe zone Figure 5. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA | ||
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 6. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to MCIO x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 7. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA | ||
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Figure 8. NVMe cable routing to system board | ||
From | To | Cable |
1 BP1: NVMe 0-1 | PCIe 1 (onboard) | SlimSAS x8 to MCIO x8 pair (820 mm/780 mm) |
2 BP1: NVMe 2-3 | PCIe 2 (onboard) | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 9. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm) |
2 BP2: SAS/SATA | ||
3 BP3: SAS/SATA | 24i G3: C2, C3 | Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm) |
Onboard NVMe/SATA + 1 x retimer + 1 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 10. NVMe cable routing to system board and top PCIe zone Figure 11. NVMe cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to MCIO x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 12. SAS/SATA cable routing to system board and PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | SATA 0-3 (onboard) | SlimSAS x4 to SlimSAS x4 (540 mm) |
2 BP2: SAS/SATA | SATA 4-7 (onboard) | SlimSAS x4 to SlimSAS x4 (540 mm) |
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x retimer + 2 x 8i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 13. NVMe cable routing to system board and top PCIe zone Figure 14. NVMe cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to MCIO x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 15. SAS/SATA cable routing to top PCIe zone Figure 16. SAS/SATA cable routing to bottom PCIe zone | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA | ||
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x retimer + 1 x 16i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 17. NVMe cable routing to system board and top PCIe zone Figure 18. NVMe cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to MCIO x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 19. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA | ||
3 BP3: SAS/SATA |
|
|
Onboard NVMe + 1 x retimer + 1 x 24i RAID/HBA
NVMe cable routing | ||
---|---|---|
Note Depending on your configuration, the adapter will be installed in top PCIe zone or bottom PCIe zone. Figure 20. NVMe cable routing to system board and top PCIe zone Figure 21. NVMe cable routing to system board and bottom PCIe zone | ||
From | To | Cable |
1 BP1: NVMe 0-1 | Retimer: C0 | SlimSAS x8 to MCIO x8 pair (700 mm/700 mm) |
2 BP1: NVMe 2-3 | Retimer: C1 | |
3 BP2: NVMe 0-1 | PCIe 3 (onboard) | SlimSAS x8 to MCIO x8 pair (325 mm/160 mm) |
4 BP2: NVMe 2-3 | PCIe 4 (onboard) |
SAS/SATA cable routing | ||
---|---|---|
Figure 22. SAS/SATA cable routing to PCIe slot 9 | ||
From | To | Cable |
1 BP1: SAS/SATA | 24i G3: C0, C1 | Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (590 mm/590 mm) |
2 BP2: SAS/SATA | ||
3 BP3: SAS/SATA | 24i G3: C2, C3 | Gen 3: Mini-SAS x4*2 to SlimSAS x4*2 (840 mm/840 mm) |